Power Transistor Inspection Procedure; How To Make Sure Of Remote Control - Mitsubishi SRK63ZEA-S1 Technical Manual

Split system, air to air heat pump type
Table of Contents

Advertisement

◆ Power transistor inspection procedure

[Use a tester with a needle indicator for the inspection. (Do not use a digital tester. Check in the AC 300 volt range.)]
1)
If there is a self-diagnosis display, inspect the compressor system (burns, wiring mistakes, etc.). If no problems are found,
check the output of the power transistor.
2)
Output inspection procedure
Disconnect the terminals for the compres-
sor. If an output such as the one shown in
the figure on the right can be measured,
the power transistor and the circuit board
for the outdoor unit are normal.
* For about 50 seconds. After being switched on,
there will be a delay of approximately one minute
depending on the conditions.

(11) How to make sure of remote control

(1)
Is remote
control normal?
YES
Again pushing
operating switch
Operating the unit?
NO
Does unit ON/OFF
button operates?
Operating the unit.
NO
Control problem on
main unit
Output voltage
NO
Remote control
defects
YES
Abnormality is not
found.
YES
(ACV)
0
8 ~ 10 sec.
Operation SW ON
Replace the display.
Is the unit
operable with remote
control?
NO
Defective remote
control
Note (1) Check method of remote control
(a)
Press the reset switch of the remote control.
(b)
If all LCD are displayed after one (1) display, it is basically normal.
65
-
-
(Example)
Self-diagnosis display : Flashes 2 times
1
Measure in this section
YES
Normal

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk71zea-s1

Table of Contents