Model SRK71ZEA-S1 (Indoor unit)
SRC71ZEA-S1 (Outdoor unit)
Item
Cooling capacity
(1)
Heating capacity
(1)
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP
Sound level
Cooling
Power level
Noise level
Sound level
Heating
Power level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
(3)
Refrigerant oil
Deice control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source supply
Size × Core number
Connection wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
The piping length is 7.5m.
(2) The operation data are applied to the 240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is longer, when it is 15 to 30 m, add 25g refrigerant per meter.
Model
W
W
kW
A
kW
A
A
dB
mm
kg
kW
kg
R
W
(Cooling)
CMM
(Heating)
Compressor overheat protection, Heating overload protection (High pressure control), Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection, Cooling overload protection
mm (in)
Mounting kit, Clean filter (Allergen clear filter × 1, Photocatalytic washable deodorizing filter × 1)
Item
Indoor air temperature
DB
27ºC
20ºC
SRK71ZEA-S1
7100 (900~8000)
8000 (900~10500)
1 Phase, 240V, 50Hz
Cooling: 3.21 Heating: 3.62
Hi 45, Me 40, Lo 34, ULo 26
60
Hi 46, Me 40, Lo 34, ULo 27
60
318 × 1098 × 248
15
Slit fins & inner grooved tubing
Capillary tubes + Electronic expansion valve
R410A 1.9 (Pre-Charged up to the piping length of 15m)
0.67 (MEL56)
Microcomputer control
Tangential fan × 1
46
20
22.5
Polypropylene net (washable) × 2
Wireless-Remote control
Microcomputer thermostat
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Liquid line: φ6.35 (1/4") Gas line: φ15.88 (5/8")
Flare connecting
Liquid line: 0.70m
Gas line : 0.63m
Necessary (Both sides)
Connectable
Terminal block (Screw fixing type)
× 4 cores (Including earth cable)
1.5 mm
2
Terminal block (Screw fixing type)
Wired-Remote control
Outdoor air temperature
WB
DB
19ºC
35ºC
7ºC
4
-
-
SRC71ZEA-S1
2.21
9.3
2.21
9.3
9.3
52
67
49
64
750 × 880 × 340
white
59
TNB220FLBM1 [Twin rotary type] × 1
1.3
Line starting
Straight fin & inner grooved turbing
Propeller fan × 1
86
56
46
Cushion rubber (for compressor)
WB
24ºC
ISO-T1, JIS C9612
6ºC
ISO-T1, JIS C9612
(240V)