(d) Changing the remote control's temperature setting range
1) The temperature setting range of the remote control can be changed.
Through remote control button operations, the upper limit and lower limit set temperature values can be changed indi-
vidually.
During heating operation, the changed upper limit value becomes valid and at times other than during heating operation,
(during cooling, dehumidification, auto and fan operation), the changed lower limit value becomes valid.
Range of Possible Changes
Upper Limit Value: 22~30°C (valid during heating) Lower Limit Value: 18 ~ 26°C (valid at times other than during
heating)
2) Operation
a) With the remote control in the stopped state, press the SET and MODE buttons simultaneously for 3 seconds or
longer. The display will changed from "
b) Press the
button once. The display will change to TEMP RANGE
c) Press the SET button to enter the temperature range setting mode.
d) Using the
or
e) If "Hi LIMIT SET" is selected,
1 The display changes from "
2 Using the "
3 Press the SET button to fix the setting. Display example: "Hi LIMIT 22°C" (lighted up)
f) If "Lo LIMIT SET" is selected,
1 The display changes from "
2 Using the "
3 Press the SET button to fix the setting. Display example: "Lo LIMIT 26°C" (lighted up)
g) Press the ON/OFF button to end the setting procedure.
(The procedure also ends if the ON/OFF button is pressed during the setting operation. However, settings which have
not been fixed become invalid, so exercise caution.)
• If the RESET button is pressed during a setting operation, the display returns to the previously displayed setting screen.
However, settings which have not been fixed become invalid, so exercise caution.
* If "NO DISP CHANGE" is selected in No. 12, "TEMP RANGE SET" of the remote control's functions, of the function
setting modes, the remote control's display does not change even if the temperature range has been changed.
(Example) If the upper limit is set at 28˚C
Function No. A
12
SELECT ITEM"
button, select "Hi LIMIT SET
SET UP"
" button, select the upper limit value. Display example: "Hi LIMIT 22°C
SET UP"
" button, select the upper limit value. Display example: "Lo LIMIT 26°C
Function Contents B
TEMP RANGE SET
NO DISP CHANGE
45
-
"
.
" or "Lo LIMIT SET
"Hi LIMIT 22°C
"Lo LIMIT 26°C
Setting Contents C
The remote control's display and sent
DISP CHANGE
data upper limit changes to 28°C.
The remote control's display upper limit
remains at 30ºC and only the upper limit
of the sent data is changed to 28°C.
-
SET"
"FUNCTION SET
," the press the SET button.
" (flashing).
" (flashing)
" (flashing).
" (flashing)
Control Contents
"