Economy Operation; Standby Operation; External Control (Remote Display)/Control Of Input Signal; Control Of Input Signal - Mitsubishi SRK63ZEA-S1 Technical Manual

Split system, air to air heat pump type
Table of Contents

Advertisement

(d) Fan operation 2
1)
Operation content
Inverter command speed
Indoor fan motor
Outdoor fan motor
Flap and louver

4.15 ECONOMY operation

(1) The set temperature is raised by 1.5°C (0.5°C every one hour) at cooling operation and lowered by 2.5°C (Steps of 1°C, 1°C and
0.5°C every one hour) at heating operation to continue the operation with the following contents.
(2) Detail of operation
Item
Operation mode
Inverter command speed
Indoor fan motor
Outdoor fan motor

4.16 External control (remote display)/control of input signal

Make sure to connect the wired remote control unit. Control of input signal is not available without the wired remote control unit.
(1) External control (remote display) output
Following output connectors (CNT) are provided on the printed circuit board of indoor unit.
(a) Operation output: Power to engage DC 12V relay (provided by the customer) is outputted during operation.
(b) Heating output: Power to engage DC 12V relay (provided by the customer) is outputted during the heating operation.
(c) Compressor ON output: Power to engage DC 12V relay (provided by the customer) is outputted while the compressor is
operating.
(d) Error output: When any error occurs, the power to engage DC 12V relay (provided by the customer) is outputted.

(2) Control of input signal

Control of input signal (switch input, timer input) connectors (CNT) are provided on the control circuit board of the indoor unit.
However, when the operation of air conditioner is under the Center Mode, the remote control by CnT is invalid.
(a) If the factory settings (Jumper wire J1 EXTERNAL INPUT on the PCB) are set, or "LEVEL INPUT" is selected in the wired
remote control's indoor unit settings.
1) Input signal to CnT OFF → ON
2) Input signal to CnT ON → OFF
CnT Input
A Unit
B Unit
(b) When Jumper wire J1 on the PCB of indoor unit is cut at the field or "PULSE INPUT" is selected in the wired remote
control's indoor unit settings.
Input signal to CnT becomes valid at OFF → ON only and the motion of air conditioner [ON/OFF] is inverted.
CnT Input
A Unit
B Unit
0 rps
OFF
2nd speed
Fully closed/ Center
(ECONO button on remote control: ON)
Model
SRK63ZEA-S1
Cooling
12~46 rps
2nd, 4th speed
ON
OFF
ON
OFF
*ON
ON
ON
OFF
OFF
ON
OFF
ON
OFF
(e) Standby operation
1)
Operation content
Inverter command speed
Indoor fan motor
Outdoor fan motor
Flap and louver
Heating
Cooling
12~60 rps
12~52 rps
3rd, 5th speed
2nd, 4th speed
3rd~5th speed
Air conditioner ON
Air conditioner OFF
ON
OFF
OFF
*ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
22
-
-
0 rps
OFF
Determined by stop mode
Fully closed/ Center
SRK71ZEA-S1
Heating
12~66 rps
3rd, 5th speed
Note (1) The ON with the * mark indicates an
ON operation using the remote control
unit switch, etc.