ALARM SETUP

1
Press the MENU button, then press the O button to
select "3. ALARM SET" and press the MENU
button again.
2
With the "ON" setting selected for "BUZZER", press
the O button.
3
Press the + (or –) button to select the desired
setting for "DURATION", then press the O button.
Following the same procedure, select the desired
settings for "RETRIGGER", "MONITOR1 ZOOM",
"MONITOR1 STILL", "VIDEO LOSS".
(For more information on each setting, please refer
to "Alarm Settings" below.)
4
Press the MENU button, then press the O button to
select "7. ENTER" and press the MENU button
again.
Alarm Settings
BUZZER
ON: The buzzer will sound when there is an alarm trigger.
OFF: The buzzer will not sound.
DURATION
The duration of the alarm can be selected by pressing the +
(or –) button.
10SEC, 20SEC, 30SEC, 40SEC, 50SEC, 60SEC, CC
CC: The alarm will go on as long as the alarm signal is
received (minimum 10 seconds).
RETRIGGER
ON: If a second alarm trigger is received during the alarm
operations for that same alarm number, it will also be
received.
OFF: During the alarm operations for an alarm number, any
alarm trigger at the same alarm number will be ignored.
English
The following operations are available when "MULTI
MODE" is set to "ON"
MONITOR1 ZOOM
When an alarm trigger is received, the display on the
monitor will switch to split screen (10 divisions) and the
image of the camera corresponding to the alarm trigger will
be zoomed in.
If the alarm trigger was recorded on tape, the image will not
be zoomed in.
OFF: The zoom function will not operate.
MONITOR1 STILL
When an alarm trigger is received, the display on the
monitor will switch to split screen (10 divisions) and the
image of the camera corresponding to the alarm trigger will
be freezed.
If the alarm trigger was recorded on tape, the image will not
be freezed.
OFF: The still function will not operate.
VIDEO LOSS
ON: An alarm is generated if there is loss of the video signal.
The display on monitor 1 will automatically switch to 10
divisions split screen, "A" will be displayed for the
camera where the loss of video signal occurred and the
ALARM DURATION will be 30 seconds. This alarm will
not be included in the ALARM DATA display.
OFF: An alarm is not generated if there is loss of the video signal.