CHAPTER 2. OPTIONS

1. OPTIONS (NO)
2. SERVICE OPTIONS (NO)
3. SUPPLIES
NO
NAME
1
Thermal roll paper
4. SPECIAL SERVICE TOOLS
NO
NAME
1
RS-232 Loop-back connector

CHAPTER 3. MASTER RESET AND PROGRAM RESET

1. MASTER RESETTING

Master resetting clears the entire memory and resumes initial values.
Master resetting can be accomplished by using the following procedure:
Procedure A: 1) Unplug the AC cord from the wall outlet.
2) Set the mode switch to the PGM position.
3) While holding down both the JOURNAL FEED key
and [CL] key, plugin the AC cord to the wall outlet.
The master reset can also be accomplished in the following case.
In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically performed
after the power has been restored.
(This is because if power failure occurs with no battery attached to
the machine, all the memories are lost and the machine does not
work properly after power recovery; this requires the master reset
operation.)
PARTS CODE
TPAPR6656RC05
PARTS CODE
UKOG-6705RCZZ
2. PROGRAM RESETTING (INITIALIZATION)
This resetting resumes the initial program without clearing memory.
This resetting can be operated at below sequence in PGM mode.
Procedure:
Note: In case power failure occurs when the machine has no battery
attached to it, the master reset operation is automatically per-
formed after the power has been restored.
XE-A302U OPTIONS
– 4 –
PRICE
DESCRIPTION
RANK
BA
5 ROLLS/PACK
PRICE
DESCRIPTION
RANK
BC
1) Unplug the AC cord from the wall outlet.
2) Set the mode switch to the PGM position.
3) While holding down both JOURNAL FEED key and
RECEIPT FEED key, plugin the AC cord to the wall
outlet.