Install The Mount, Adapter Or Bracket; Install The Housing - Honeywell equip acuix Quick Installation Manual

Ip ptz dome

Advertisement

2

Install the Mount, Adapter or Bracket

Pendant and Rugged Installations Only
See
Use the hole pattern on the mount, adapter or bracket to drill holes
1
in the wall, ceiling or roof. Use the appropriate hardware for the
B
mounting surface and follow all installation warnings and cautions
C
on the first page.
To prevent water leakage with outdoor installations, apply sealant
2
to around all the holes between the mount, mount and the adapter,
and any mounting surface. For wall mount installations also
confirm that the pre-installed gasket on the base of the mount is in
place.
For rugged domes, the bracket can be installed at any angle from
3
0° to 90° with respect to the housing; ensure the housing itself is
positioned horizontally and parallel to the floor.
If required for rugged dome installations, secure an installer
4
supplied safety cable to a building support. A 3/32" (2.5 mm)
plastic coated aircraft cable is recommended.
3

Install the Housing

Indoor and Outdoor Pendant
See
Route field wiring from mount through top of housing.
1
B
To prevent threads from binding, wrap the threaded nipple with
2
Teflon® tape. Thread housing onto mount.
Rugged
Install a 0.75" (19 mm) conduit fitting on the housing.
1
C
Place the gasket between the hole and the conduit fitting. Tighten the conduit
2
nut and ensure water tight.
Route the field wiring through the hole in the side of the housing. Secure the
3
housing to the mounting bracket.
In-ceiling (Dropped or Hard Ceiling)
Cut a 7 5/8" (194 mm) hole in ceiling using the template provided. Seal
D
1
perimeter to stop dust or debris from falling from ceiling. For dropped ceilings,
remove ceiling plate and place on dropped ceiling tile. Trim the tile and press
into the plate.
If required, secure an installer supplied safety cable to a building support. A
2
3/32" (2.5 mm) plastic coated aircraft cable is recommended.
Place tile (including the plate for dropped ceilings, part number 517082-7130)
3
and housing on the ceiling grid supports. Insert through hole with wing tabs flat.
Rotate tabs clockwise to tighten against ceiling. Ensure the space between wing
tab and housing is greater than ceiling thickness, and the wing tabs are staggered
to different heights.
2
Indoor pendant and in-ceiling: Ensure a 24 VAC @ 2.0 A power source is available.
Outdoor pendant and rugged: Ensure a 24 VAC @ 2.6 A power source is available.
B
Indoor and Outdoor Pendant
Mounts and Adapters
Pole adapter *
Parapet or
roof mount
Ceiling mount
(indoor only)
Wall mount
Corner adapter *
Housing and Lower Dome
Lower dome
Indoor
Outdoor
The corner and pole adapters can be used with
the pendant wall mount or the rugged bracket
The new V2 pendant housings and
lower dome models MUST be
installed with each other.
Rugged Dome Housing
C
with Mounting Bracket
Mounting bracket
(included with
housing)
Housing
In-Ceiling Housing*
D
Indoor in-ceiling
housing
Lower dome
*For a dropped ceiling
use a ceiling plate
800-01115 Rev B (07-2009)