THE NO VOLT RELEASE (NVR) SWITCH FOR
THE DRILL PRESS (FIG. Q, Q-1, Q-2)-ONLY FOR
SINGAPORE, MALAYSIA, INDONESIA, SAUDI
ARABIA
Your drill press is equipped with a No Volt Release
(NVR) switch with emergency stop cover. This device
can provide to stop the dill press immediately in urgent
condition.
The main switch , No Volt Release (NVR) switch
(1-Fig. Q), is on the front of drill head. Press " I " to turn
on the power; press "O" to turn off the power. When the
power breaks off accidentally, press " I " to restart. The
emergency stop cover (2 - Fig. Q-1) will allow you to
stop the operation of this drill press in ugent condition by
hitting it by hand.
Fig. Q
Fig. Q-1
An interlock (micro) switch (3-Fig. Q-2 ), which will cut off
the power when the lockable pulley cover is opened, is
equipped with the drill press for double protection from
the possible injury caused by the moving parts inside the
pulley cover.
To avoid possible injury, always keep the pulley cover
closed and locked with the screw provided.
Drawing shows
the emergency
stop cover
removed
1
2
WARNING
Fig. Q-2
ON / OFF SWITCH PANEL (FIG. Q-3)-ONLY FOR
AUSTRALIA AND NEW ZEALAND
The "ON / OFF" switch has a removable, safety key.
With the key removed from the switch, unauthorized and
hazardous use by children and others is minimized.
1. To turn the drill press "ON", insert the key (2) into the
slot of the switch (1), and move the switch upward to
the "ON" position.
2. To turn the drill press "OFF", move the switch
downward.
3. To lock the switch in the "OFF" position, grasp the
safety key of the toggle switch and pull it out.
4. With the switch key removed, the switch will not
operate to power the drill press on.
5. If the switch key is removed while the drill press
is running, it can be turned "OFF" but cannot be
restarted without inserting the switch key.
6. To turn the worklight "ON", press the rocker switch (3)
to the on position.
7. Never leave the drill press unattended. Turn the light
switch and power switch "OFF" and wait until it comes
to a complete stop, and remove the safety key to
prevent unauthorized starts.
Fig. Q-3
ALWAYS lock the switch "OFF" when the drill press is
not in use. Remove the key and keep it in a safe place.
In the event of a power failure, blown fuse, or tripped
circuit breaker, turn the switch "OFF" and remove the key,
preventing an accidental startup when power comes on.