Cabinet Dimension Requirements
Dimensions
for 27" Wall-Mounted
Units
Single Oven 27"
Double Oven 27"
50"
_'_
(1270)
m&x. 38"
p
(121-964
29"
269/16"
(737)
(674)
.....
-_(568)
*
For single ovens installed in a wall cabinet, the junction
box may be located above or beneath the unit within
reach of the power cable.
Flush installation requires two side cleats to be attached
inside the cabinet frame, recessed from the front.
Flush Install
Top View
Side View
!/8"
(22)
7/d' (22)
I_ats
cleats
(;5
_
251'2" (648) _1
-FF...............
qq-
27_/4" (692)
et
89/16"
(218)
24518"
(625)
i(674)--'_-
II
J
i_r°g uct I
II
__
241/2".___
(622)
1"
c!9_t,
(25)
29114"
(744)
flush
cut out
height
!
measurements
in inches (ram)
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 114" space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box can be installed above or to the right of the
unit, within range of the power conduit.
The cabinet cavity must be plumb and the base must be flat
and level and capable of supporting a weight of at least 193
Ibs (87 kg).
rain.
(121
*
For single ovens installed in a wall cabinet, the junction
box may be located above or beneath the unit within
reach of the power cable.
Flush installation requires two side cleats to be attached
inside the cabinet frame, recessed from the front.
Flush
installation
Top view
241/2"
(622)
Flush
inset
depth
Side view
89/16"
Cleats
'&
493/4
"
(t264)
495/8"
Openin{
(1260)
cut-out
4711/16.
P_°dih_t
night
(1211)
:
24112"
(622)
1"
_5_
52 3/8"
1330)
F ush
cut-out
height
measurements
in inches
(ram)
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 114"space between the side of the
oven and the wall/door.
For oven support, install 2x4's extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be located above the unit to facilitate
connecting and servicing.