(9) Apply Froil G-311S to the upper sur-
face of the PF cam gear.
(10) Install the return ring and the PF6D
cam in the PF cam gear and secure it
with the E-ring.
(11) Apply Froil G-311S to the outside and
surfaces of the PF6D cam.
(12) Insert the pressure roller in the pres-
sure roller shaft and set it in the frame
assembly.
Note: The pressure roller must be set
in the notched hole of the frame
assembly.