Other methods of setting the IP address

All the methods listed the table below are enabled by default, and can be disabled.
Use in
operating
system
Windows
UPnP™
MAC OSX
Bonjour
(10.4 or later)
All
AXIS
Dynamic DNS
Service
All
ARP/Ping
All
View DHCP
server admin
pages

Set the IP address with ARP/Ping

1. Acquire an IP address on the same network segment your computer is connected to.
2. Locate the serial number (S/N) on the camera's label.
3. Open a command prompt on your computer and enter the following commands:
Windows syntax
arp -s <IP Address> <Serial Number>
ping -l 408 -t <IP Address>
UNIX/Linux/Mac syntax
arp -s <IP Address> <Serial Number> temp
ping -s 408 <IP Address>
4. Check that the network cable is connected to the camera and then start/restart the camera, by
disconnecting and reconnecting power.
5. Close the command prompt when you see 'Reply from 192.168.0.125: ...' or similar.
6. In your browser type http://<IP address> in the Location/Address field and press Enter.
Notes
When enabled on your computer, the camera is automatically
detected and added to "My Network Places."
Applicable to browsers with support for Bonjour. Navigate to the
Bonjour bookmark in your browser (e.g. Safari) and click on the link
to access the camera's web pages.
A free service from Axis that allows you to quickly and simply install
your camera. Requires an Internet connection with no HTTP proxy.
See www.axiscam.net for more information.
See below. The command must be issued within 2 minutes of
connecting power to the camera.
To view the admin pages for the network DHCP server, see the
server's own documentation.
Windows example
arp -s 192.168.0.125 00-40-8c-18-10-00
ping -l 408 -t 192.168.0.125
UNIX/Linux/Mac example
arp -s 192.168.0.125 00:40:8c:18:10:00 temp
ping -s 408 192.168.0.125