Error Log - Sanyo PLC-WM4500L Service Manual

Hide thumbs Also See for PLC-WM4500L:
Table of Contents

Advertisement

Troubleshooting

Error Log

This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select Group No. "220" and Item No. "0" to "49". The error
code is displayed on the Data column. The description of
the error code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
error
error code
Normal
0
1000
1001
1002
1003
Power Failure
1004
1005
1006
1007
1008
2000
2001
2100
2101
Temperature Error
2102
2200
2201
2202
3000
Lamp Error
3001
3002
How to reset the error Log
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".
error Infomation
(See Powe Failure Detection System)
-
PF_IC_S3.3V
PF_LNS
PF_MAIN
PF_12V_ID
AV,
S-6V
PF_FAN
MAIN,
5V
LAN,
3.3V
FILTER,
DET
Sensor A detects abnormal temperature. (IC1692-ROOM)
Sensor A fails measurement. (IC1692)
Sensor B detects abnormal temperature. (IC1816-LAMP)
Sensor B fails measurement. (IC1816)
Sensors B-A temperature error.
Sensor C detects abnormal temperature. (IC1814-PANEL)
Sensor C fails measurement. (IC1814)
Sensors C-A temperature error.
Lamp1 fails on
Lamp1 goes out
Communication Error on Lamp1
-82-
Item
Data
Group
No.
(Error Code)
No.
220
0
1
2
3
:
:
:
:
49
error Infomation
error code
(See Powe Failure Detection System)