Sanyo PLC-WM4500L Service Manual page 53

Hide thumbs Also See for PLC-WM4500L:
Table of Contents

Advertisement

Electrical Adjustment
Grp / No. Item
4
DIMMER_CTRL_LEVEL3
5
DIMMER_CTRL_LEVEL4
6
DIMMER_CTRL_LEVEL5
7
DIMMER_CTRL_LEVEL6
8
DIMMER_CTRL_LEVEL7
9
DIMMER_CTRL_LEVEL8
10
DIMMER_CTRL_LEVEL9
11
DIMMER_CTRL_LEVEL10
12
DIMMER_CTRL_LEVEL11
13
DIMMER_CTRL_LEVEL12
14
DIMMER_CTRL_LEVEL13
15
DIMMER_CTRL_LEVEL14
16
DIMMER_CTRL_LEVEL15
17
DIMMER_AVERAGE_POINT
18
DIMMER_AVERAGE_DATA
19
DIMMER_LEVEL_AUTO
20
DIMMER_LEVEL_NORMAL
21
DIMMER_LEVEL_ECO
23
VOLTAGE_LEVEL
220
Projector Error Log
0
Warning_Log_1
:
:
49
Warning_Log_50
50
Warning_Log Reset
249
Pressure Sensor
0
Pressure Monitor
1
Pressure Moniture
2
Press Offset
3
Press Calib Effective Diff
4
Press Sensor Calibration Log
250
Fan Voltage Adjustment
0
Fan 1 Min Adjust (DAC)
1
Fan 1 Max Adjust (DAC)
2
Fan 2 Min Adjust (DAC)
3
Fan 2 Max Adjust (DAC)
4
Fan 3 Min Adjust (DAC)
5
Fan 3 Max Adjust (DAC)
6
Fan 4 Min Adjust (DAC)
7
Fan 4 Max Adjust (DAC)
8
Fan 5 Min Adjust (DAC)
9
Fan 5 Max Adjust (DAC)
10
Fan 6 Min Adjust (DAC)
11
Fan 6 Max Adjust (DAC)
12
Fan 7 Min Adjust (DAC)
13
Fan 7 Max Adjust (DAC)
252
Fan Option
1
Safety Switch
2
Fan Manual Switch
3
Fan1 Manual Voltage
4
Fan2 Manual Voltage
5
Fan3 Manual Voltage
6
Fan4 Manual Voltage
7
Fan5 Manual Voltage
8
Fan6 Manual Voltage
9
Fan7 Manual Voltage
10
Angle Data A
11
Angle Data B
12
Press Data
253
Fan Temp Error Setting
5
Temp A Warning (Normal)
6
Temp B Warning (Normal)
Function
Y Level3 Data for Dimmer
Y Level4 Data for Dimmer
Y Level5 Data for Dimmer
Y Level6 Data for Dimmer
Y Level7 Data for Dimmer
Y Level8 Data for Dimmer
Y Level9 Data for Dimmer
Y Level10 Data for Dimmer
Y Level11 Data for Dimmer
Y Level12 Data for Dimmer
Y Level13 Data for Dimmer
Y Level14 Data for Dimmer
Y Level15 Data for Dimmer
Y Average Point
Y Average Data (Read only)
Current Y Level (Read only)
Dim Level at Normal
Dim Level at Eco
Lamp Voltage (Read only)
Latest Error log
:
50th Error log
Log is cleared when the value is set to 10.
Pressure Value (Original) [ADC]
Pressure Value (Compensated)[ADC]
Offset Value
Effective Range of Calibration
Calibration LOg
0: Excuted and Adquate Offset Value
10:Out of Range (Mini)
20: Out of Range (Max)
99: Not executed
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
Angle Data A (Read only)
Angle Data B (Read only)
Air Pressure Data (Read only)
(Memorized)
Temp A (Room) to judge the Temp Error at Normal
Temp B (Lamp) to judge the Temp Error at Normal
Range
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 16
-
-
0 - 15
0 - 15
-
0 - 32767
:
0 - 32767
0 - 10
-
-
-1023 - 1023
0 - 1023
-
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-6
0-1
0-145
0-145
0-145
0-145
0-145
0-145
0-145
-
-
-
Normal
30-100
48
30-100
70
-53-
Initial
Note
21
28
35
42
49
56
63
70
77
84
91
98
105
4
-
-
15
0
-
0
:
0
0
-
-
0
1023
99
* Fan voltage adj.
84
237
83
240
40
244
40
230
41
232
43
233
39
229
0
0
100
100
100
100
100
100
100
-
-
-
Ceiling
Top
Bottom
47
47
47
70
70
70

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wm4500

Table of Contents