Electrical Adjustment
Grp / No. Item
7
Temp C Warning (Normal)
8
Temp B-A Warning (Normal)
9
Temp C-A Warning (Normal)
10
Temp A Warning (Eco)
11
Temp B Warning (Eco)
12
Temp C Warning (Eco)
13
Temp B-A Warning (Eco)
14
Temp C-A Warning (Eco)
15
Temp A Warning Offset (Temp)
16
Temp B Warning Offset (Temp)
17
Temp C Warning Offset (Temp)
18
Temp B-A Warning Offset (Temp)
19
Temp C-A Warning Offset (Temp)
20
Temp A Warning Offset (Time)
21
Temp B Warning Offset (Time)
22
Temp C Warning Offset (Time)
23
Temp B-A Warning Offset (Time)
24
Temp C-A Warning Offset (Time)
254
Fan Control Range Setting (Temp/Spinning)
16
Normal Fan Control Min Temp
17
Normal Fan Control Max Temp
18
Normal Fan1 Min
19
Normal Fan1 Max
20
Normal Fan2 Min
21
Normal Fan2 Max
22
Normal Fan3 Min
23
Normal Fan3 Max
24
Normal Fan4 Min
25
Normal Fan4 Max
26
Normal Fan5 Min
27
Normal Fan5 Max
28
Normal Fan6 Min
29
Normal Fan6 Max
30
Normal Fan7 Min
31
Normal Fan7 Max
32
Eco Fan Control Min Temp
33
Eco Fan Control Max Temp
34
Eco Fan1 Min
35
Eco Fan1 Max
36
Eco Fan2 Min
37
Eco Fan2 Max
38
Eco Fan3 Min
39
Eco Fan3 Max
40
Eco Fan4 Min
41
Eco Fan4 Max
42
Eco Fan5 Min
43
Eco Fan5 Max
44
Eco Fan6 Min
45
Eco Fan6 Max
46
Eco Fan7 Min
47
Eco Fan7 Max
255
Fan Start/Cooling Setting
0
Fan1 Initial Volt
1
Fan2 Initial Volt
2
Fan3 Initial Volt
3
Fan4 Initial Volt
4
Fan5 Initial Volt
5
Fan6 Initial Volt
6
Fan7 Initial Volt
Function
Temp C (Panel) to judge the Temp Error at Normal
Temp B - A (Filter Clogged) to judge the Temp Error at Normal
Temp C - A (Filter Clogged) to judge the Temp Error at Normal
Temp A (Room) to judge the Temp Error at Eco
Temp B (Lamp) to judge the Temp Error at Eco
Temp C (Panel) to judge the Temp Error at Eco
Temp B - A (Filter Clogged) to judge the Temp Error at Eco
Temp C - A (Filter Clogged) to judge the Temp Error at Eco
Temp Warning Offset (Temp)
Time Warning Offset (Time)
Temp Sensor Control Start/End Temp at Normal
Fan Spinning Set at Normal (Min/Max) (0.1V)
Temp Sensor Control Start/End Temp at Eco
Fan Spinning Set at Eco (Min/Max) (0.1V)
Fan Start Voltage (0.1V)
Range
30-100
65
0-100
100
0-100
100
30-100
47
30-100
68
30-100
63
0-100
100
0-100
100
0-100
0-100
0-100
0-100
0-100
0-40
0-40
0-40
0-40
0-40
Normal
20-100
25
20-100
37
0000-9990
70
0000-9990
138
0000-9990
60
0000-9990
138
0000-9990
40
0000-9990
40
0000-9990
60
0000-9990
138
0000-9990
70
0000-9990
100
0000-9990
70
0000-9990
70
0000-9990
56
0000-9990
98
20-100
25
20-100
36
0000-9990
45
0000-9990
120
0000-9990
42
0000-9990
120
0000-9990
40
0000-9990
40
0000-9990
45
0000-9990
120
0000-9990
55
0000-9990
80
0000-9990
50
0000-9990
50
0000-9990
45
0000-9990
98
0-145
0-145
0-145
0-145
0-145
0-145
0-145
-54-
Initial
Note
65
65
65
100
100
100
100
100
100
48
47
47
69
68
68
64
63
63
100
100
100
100
100
100
10
11
13
11
13
30
25
30
15
15
110°
70°
Top
Normal
Ceiling
Bottom
290°
250°
Ceiling
Top
Bottom
25
25
25
36
36
36
70
70
70
138
138
138
60
60
60
138
138
138
70
70
40
70
70
40
60
60
60
138
138
138
70
70
70
100
100
100
40
40
70
40
40
70
56
65
56
98
98
98
25
25
25
36
36
36
45
45
45
120
120
120
42
42
42
120
120
120
50
50
40
50
50
40
45
45
45
120
120
120
55
55
55
80
80
80
40
40
50
40
40
50
50
55
45
98
98
98
45
45
70
45
65
70
55