SECTION 3
EMERGENCY PROCEDURES
3.5g Electrical Fire (3.21) (Continued)
Flashlight (at night) ........................................................................LOCATE
Battery Master ........................................................................................OFF
Alternator Switches ................................................................................OFF
All Electrical Switches ...........................................................................OFF
Radio Master Switch ..............................................................................OFF
Vents .................................................................CLOSED (To avoid drafts)
Cabin Heat ..............................................................................................OFF
If fire persists, locate and, if practical, extinguish with portable fire
extinguisher locate on the console just aft of the 2 front seats.
Bus Tie Circuits Breakers
Both Main Bus..............................................................................PULL
Non-essential ................................................................................PULL
Avionics Bus # 1 ...........................................................................PULL
Avionics Bus # 2 ...........................................................................PULL
L. Alternator .................................................................................PULL
R. Alternator .................................................................................PULL
All Main Bus Circuit Breakers ............................................................PULL
All Avionics Bus Circuit Breakers.......................................................PULL
At this point, the pilot must decide if the flight
can be safely continued without electrical power.
If so, land at the nearest airport and have the
electrical system repaired.
If electrical power is required for safe continuation of flight, proceed
as follows:
The following procedure may reenergize the
faulty system. Reset the circuit breaker one at a
time. Allow a short time period between the
resetting of each breaker. If the faulty system is
reinstated, its corresponding circuit breaker must
be immediately pulled.