5. Spray the energy transfer wheel thoroughly with household spray
cleaner (Fantastic™ or equivalent). Rinse with warm water. Use
a soft brush to remove stains between the plastic windings.
Shake excess water from the wheel.
6. Replace the wheel on the drive shaft.
NOTE: Rotate the wheel counterclockwise until the pin in the shaft has
engaged in the slot in the bottom of the hub. The end of the drive
shaft and the face of the hub will be flush.
Fig. 5—ER90/100 Energy Trans-
fer Wheel and belts location.
ENERGY
ENERGY TRANSFER
TRANSFER
WHEEL HUB CAP
WHEEL
DRIVE BELT SET
Fig. 6—ER200 Energy Transfer
Wheel and belts location.
ENERGY
TRANSFER WHEEL
WHEEL DRIVE
BELT
WHEEL DRIVE
PULLEY
WHEEL DRIVE
MOTOR
7. Put hub cap on, rotate
8. Install the center divider.
9. Replace the Home
To remove and clean the
BLOWER
ER200 Energy Transfer
AND
MOTOR
Wheel:
1. Unscrew the screws
M3325
2. Take out the center
3. Remove the belt from
4. Unscrew the screw in
5. Use the rim of the wheel
6. Spray the energy
M3322A
8
in clockwise direction,
tighten screw.
Ventilation System
cover and tighten the
screws.
holding the ventilator
door and open the door.
divider.
the rim of the wheel.
See Fig. 6.
the center of the hub.
and lift the wheel
straight off the drive
shaft.
transfer wheel thor-
oughly with household
spray cleaner (Fantas-
tic™ or equivalent).
Rinse with warm water.
Use a soft brush to
remove stains between

Hide quick links: