9.1 Cleaning the filters

B

9.2 Cleaning the spray arms

Do not remove the spray arms.
If the holes in the spray arms are clog-
ged, remove remaining parts of soil with
a thin pointed object.

9.3 External cleaning

Clean the appliance with a moist soft
cloth.

10. TROUBLESHOOTING

The appliance does not start or it stops
during operation.
Before you contact the Service, refer to
the information that follows for a solu-
tion to the problem.
1.
Turn the filter (A) counterclockwise
and remove it.
C
A
2.
To disassemble the filter (A), pull
apart (A1) and (A2).
3.
Remove the filter (B).
A1
4.
Wash the filters with water.
5.
Put the filter (B) to its initial position.
Make sure that it assembles correct-
ly under the two guides (C).
A2
6.
Assemble the filter (A) and put it in-
to position in filter (B). Turn it clock-
wise until it locks.
Only use neutral detergents. Do not use
abrasive products, abrasive cleaning
pads or solvents.
With some problems, the display
shows an alarm code:
water.
An incorrect position of the filters
can cause bad washing results
and damage to the appliance.
- The appliance does not fill with
ENGLISH