Alarm And Sensor Setting - Sanyo MPX-MS92P Instruction Manual

Table of Contents

Advertisement

ALARM AND SENSOR SETTING

(ALARM SET)
When an alarm trigger is received from sensors such as a door
bell, movement sensor, etc. you can set the display mode and
the recording mode for the pictures from the concerned camera.
Using the (SENSOR SET) settings (see page 29), the triggers
received from the video sensors can be set to operate as alarm
triggers.
Changing the Settings
1
Press the MENU button 4 times to display the (ALARM
SET) menu.
2
Using the + (or –) button, select the desired setting,
then press the l button.
Repeat step 2, until all the settings are as desired.
3
Press the l button to go to the (SENSOR SET)
menu, or
Press the MENU button to go to the next menu
screen, or
Press the EXIT button to exit the menu display.
2
(ALARM SET)
DURATION
RETRIGGER
BUZZER
DATA
MON OUT
DOUBLE ALARM
ALARM SET menu
DURATION
(Default setting: 10 S)
The available durations are (seconds):
1, 2, 3, 4, 5, 10, 20 (in 10 seconds increments)... 180,
CC, NC, INDIV., OFF
CC:
The alarm will go on as long as the alarm signal is
received (minimum 1 second).
NC:
The alarm will continue until reset.
INDIV.:The alarm duration will be as set for each of the cameras.
OFF: No alarm duration setting.
NOTE: If the "INDIV." setting is used, in the (CAMERA SET)
menu, enter the desired alarm duration for each
camera (see page 33).
(CAMERA SET)
TITLE
PROGRAM REC
AL.DURATION
MON.MASK
RETRIGGER
(Default setting: OFF)
To set if an alarm is received while the unit is already in alarm
mode.
ON: During alarm mode, other alarm triggers will be received
and the alarm duration will be extended.
OFF: The unit will not receive another alarm, while one is
already being received.
BUZZER
(Default setting: ON)
ON: A buzzer will be heard when an alarm trigger is received.
OFF: The buzzer will not be heard.
10 S
OFF
ON
ON
FULL
LAST
NO.01
01
--------
DAY
NIGHT
OFF
OFF
10 S
10 S
OFF
OFF
DATA
(Default setting: ON)
ON: The alarm data is recorded.
OFF: The alarm data is not recorded.
MON OUT
In the MONITOR SET menu, when MULTI MODE is set to ON,
set MONITOR OUT to FULL, MULTI 9 or NC.
(A)
(ALARM SET)
DURATION
10 S
RETRIGGER
OFF
BUZZER
ON
DATA
ON
MON OUT
FULL
DOUBLE ALARM
LAST
(SENSOR SET)
SENSOR ALARM
OFF
SENSOR DURATION
10 S
(B)
(ALARM SET)
DURATION
10 S
RETRIGGER
OFF
BUZZER
ON
DATA
ON
MON OUT
MULTI9
(A) FULL (Default setting):
If an alarm trigger is received, the picture from the camera
corresponding to the alarm input will be displayed full
screen.
DOUBLE ALARM (Default setting: LAST)
When using the "FULL" setting at the "MON OUT" line,
the following settings are possible.
LAST: When triggers from multiple cameras are
received in full screen mode, the picture from the
camera of the last alarm received is displayed.
FIRST: When triggers from multiple cameras are
received in full screen mode, the picture from the
camera of the first alarm received only is displayed.
Camera pictures from subsequent alarm triggers will
not be displayed.
SWITCH: When triggers from multiple cameras are
received in full screen mode, the picture from each
concerned camera will be displayed sequentially at 1
second interval.
(B) MULTI9: When an alarm trigger is received, the display
will switch to a 9 divisions screen.
(C) NC: The display mode will remain unchanged when an
alarm trigger is received.
28
Menu 4
(C)
(ALARM SET)
DURATION
10 S
RETRIGGER
OFF
BUZZER
ON
DATA
ON
MON OUT
NC
English