INSTALLER : THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED IN CANADA TO CAN/CSA 22.2 #B40.0 - M87 &·R91 B140.1 & B140.3 CERTIFIED·IN THE UNITED STATES TO UL 896 -199
INSTALLATION AND OPERATION
INSTRUCTIONS FOR
OIL-FIRED CAST IRON STOVE
MODEL OS10-3
Installation and Service must be performed by a Qualified Installer, Service Agency or the Oil Supplier
WOLF STEEL LTD., RR#1, 24 NAPOLEON RD.,
BARRIE, ON., CANADA L4M 4Y8 (705)721-1212
Fax: (705)722-6031
Email : ASK@NAPOLEON.ON.CA
Document n° 1092-1 EN ~ 04/02/2002
Web: WWW.NAPOLEONFIREPLACE.COM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OS10-3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Napoleon OS10-3

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS FOR OIL-FIRED CAST IRON STOVE MODEL OS10-3 Installation and Service must be performed by a Qualified Installer, Service Agency or the Oil Supplier WOLF STEEL LTD., RR#1, 24 NAPOLEON RD., BARRIE, ON., CANADA L4M 4Y8 (705)721-1212 Fax: (705)722-6031 Email : ASK@NAPOLEON.ON.CA...
  • Page 2: Table Of Contents

    INTRODUCTION • The stove is an oil-fired stove. Do not burn wood or other materials in this stove. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove.
  • Page 3 NAPOLEON oil stoves are manufactured under the strict Standard of the World Recognized NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete stove is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON.
  • Page 4: General Information

    General information Oil consumption ** Nominal heat output max speed 34.100 BTU/hr .31 US gal/hr 10 kW 1.20 litre/h Nominal heat output 29 000 Btu/h (8.50 kW) ** 1 pint = 0.568 litre 1 quart = 1.136 litres 1 litre = 1.760 pints 1 litre = 0.879 quart Pints, quarts and gallons are Canadian unless otherwise noted.
  • Page 5: Location And Clearances

    Document n° 1092-1 EN ~ 04/02/2002 Location and clearances If the stove is to be installed on a combustible floor, it must be installed on sheet metal or a tile. The oil drip tray, 72636 (not supplied) is a suitable substitute for either of these two pads. Maintain these minimum clearances to combustibles (fig.
  • Page 6: Chimney Specifications

    THE TOTAL SMOKE PIPE LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE TO A MAXIMUM HORIZONTAL RUN OF 10 FEET. All smoke pipe must slope upwards at a minimum of 1/4" per foot (6 mm/0.3m) and all connections must be tight and secured by three sheet metal screws equally spaced.
  • Page 7: Finishing

    FINISHING Mounting flue collar The stove is supplied with a connection flue at rear. Smoke exit on top (figure 12, page 8) : - Remove the internal baffles on top (see page 11). - Fix the sealing rope in the groove on the top (2) and fit the flue spigot (1), ensuring there is a good seal.
  • Page 8 The fuel system of this stove is designed to supply fuel by gravity pressure only. If the supply tank location is lower than the stove, it will be necessary to use the Napoleon SP32 suction pump. The SP32 should be installed a minimum of 12" above the stove carburetor and a minimum of 6"...
  • Page 9: Operating Instructions

    OPERATING INSTRUCTIONS Understanding your oil stove Furnace oil is fed from the tank to the burner floor ‘A’ where is it ignited by means of a firestarter. The heat produced by this flame brings the burner temperature to the required level to vaporize the fuel.
  • Page 10: Shut Down

    Shut down 1. Turn the control knob to “0" setting. 2. Lift the safety lever. 3. Turn off the oil tank fuel supply valve. The oil tank fuel supply valve should always be shut off when the oil stove is not in operation. ADJUSTMENTS Oil flow adjustments The oil flow setting is done by the manufacturer and...
  • Page 11: Maintenance

    MAINTENANCE Seasonal maintenance WEEKLY - DESCALE Push and pull the de-scaling lever in and out as well as turning slightly at the same time completely two or three times. Push in for normal burner operations or before relighting. EVERY 3 TO 4 MONTHS - CLEAN BURNER Remove all three catalyser components (C, D, E, figure 13).
  • Page 12: Replacements

    For warranty replacement parts, a photocopy of the original invoice will be required to honour the claim. Ordering Replacement Parts. When ordering spare parts, please indicate model number, colour code, parts description, and code number. A = OS10-3 J (Green) B = OS10-3 K (Blue) N° Code .
  • Page 13 Document n° 1092-1 EN ~ 04/02/2002...
  • Page 14 38 306273 77 . . Back wall........c ... 01 38 306273 76 .
  • Page 15 Document n° 1092-1 EN ~ 04/02/2002 Notes...
  • Page 16: Trouble Shooting

    TROUBLE SHOOTING SYMPTOM Flames extinguish during lighting. Fire extinguishes once firestarter has burnt off. Fire extinguishes during use. Flame is excessely large, smokey and sooty. Stove burns noisily, extinguishes and relights itself. Fire smokes.Soot build up noticed. Flame imbalance Coke build up noticed. Document n°...