HORIZONTAL TERMINATION
when (H
) > (V
)
T
T
Simple venting confi guration (only one 45º and 90° elbow)
See graph to determine the required
vertical rise V
for the required hori-
T
zontal run H
.
T
REQUIRED
VERTICAL
RISE IN
INCHES (V
)
T
HORIZONTAL VENT RUN PLUS OFFSETS IN FEET
The shaded area within the lines represents acceptable values
for H
and V
.
T
T
For vent confi gurations requiring more than one 45º and 90° elbow
the following formulas apply:
Formula 1: H
< 4.2 V
T
T
Formula 2: H
+ V
< 24.75 feet
T
T
Example 2:
FIGURE 9
FIGURE 8
V
1
V
2
V
T
H
1
H
2
H
3
H
4
H
R
H
O
H
T
H
+ V
T
Formula 1:
Formula 2:
Since both formulas are met, this vent confi guration is ac-
ceptable.
90°
90°
H
1
90°
V
1
45°
= 4 ft
= 1.5 ft
= V
+ V
= 4 ft + 1.5 ft = 5.5 ft
1
2
= 2 ft
= 1 ft
= 1 ft
= 1.5 ft
= H
+ H
+ H
+ H
= 2 + 1 + 1 + 1. 5 = 5.5 ft
1
2
3
4
= .03 (one 45º elbow + four 90º elbows -135º)
=.03 (405-135)=8.1ft
= H
+ H
= 5.5 + 8.1 = 13.6ft
R
O
= 13.6 + 5.5 = 19.1 ft
T
H
< 4.2 V
T
T
4.2 V
= 4.2 x 5.5 = 23.1 ft
T
13.6 < 23.1
H
+ V
< 24.75 feet
T
T
19.1 < 24.75
11
90°
H
4
H
V
3
2
H
2
W415-0326 / C / 11.23.07