Napoleon BGD36CFNTR Installation And Operating Instructions Manual page 15

Napoleon fireplaces gas fireplace installation and operating instructions
Table of Contents

Advertisement

BGD36CF(G) TOP OR REAR EXIT VERTICAL TERMINATION
Example 8:
90°
H
2
V
1
H
1
90°
45°
H
3
FIGURE 33
V
= 1.5 ft
1
V
= 5 ft
2
V
= V
+ V
= 1.5 + 5 = 6.5 ft
T
1
2
H
= 1 ft
1
H
= 1 ft
V
2
2
H
= 10.75 ft
3
H
= H
+ H
+ H
= 1 + 1 + 10.75 = 12.75 ft
R
1
2
3
H
= .03 (three 90° elbows + one 45° elbow - 90°)
O
= .03(90 + 90 + 90 + 45 - 90) = 6.75 ft
90°
H
= H
+ H
= 12.75 + 6.75 = 19.5 ft
T
R
O
H
+ V
= 19.5 + 6.5 = 26 ft
T
T
Formula 1:
H
< 3V
T
19.5 < 19.5
Formula 2:
H
+ V
T
26 < 40
Since both formulas are met, this vent confi guration is accept-
able.
T
3V
= 3 x 6.5 = 19.5 ft
T
< 40 feet
T
W415-0661 / C / 02.20.08