6.
trOUBlesHOOtiNG
FAUlt
1a) Pressure drop in the tank
1B) Pressure drop in the tank
1c) Pressure drop in the tank
2) Pressure switch valve leaks when
compressor is idle
3) air leaks from tank body or tank welds
4a) motor stops and will not restart
4B) motor stops and will not restart
4c) motor stops and will not restart
5) compressor stops and does not restart
6a) compressor does not stop at max. pressure
6B) compressor does not stop at max. pressure
7) compressor noisy with metallic knock
8) excessive moisture in discharged air
7.
DeClArAtiON OF CONFOrMitY
Declaration of Conformity We, the sole uK importer, declare that the product listed below is in conformity with the following
standards and directives.
six litre COMPressOr
Model: sA2306
2006/42/ec machinery directive
87/404/eec Pressure Vessel directive
2004/108/ec emc directive
2006/95/ec low Voltage directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPOrtANt: no liability is accepted for incorrect use of this equipment
WArrANtY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
iNFOrMAtiON: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
CAUse
air leaks at connections
air leaks from safety valve
air leaks from cylinder head gasket
non-return valve seal defective
Internal corrosion caused by infrequent tank
draining or non permitted modifications to tank
thermal cut out has operated
supply fuse has tripped
current overload trip has operated
motor failure
Pressure switch fault
filter clogged
head gasket or valve fault
Bearing or piston damage
high humidity environment
the construction file for this product is held by the manufacturer
and may be inspected, by a national authority, upon request
to Jack sealey ltd.
signed by mark sweetman
For Jack Sealey Ltd. Sole UK importer of Sealey Power Products.
sole UK Distributor
sealey Group,
Bury st. edmunds, suffolk.
01284 703534
reMeDY
run compressor to max. pressure, switch off.
Brush soap solution over connections and look for
bubbles. tighten connections showing leaks.
If problem persists contact authorised service agent.
operate the safety valve manually by pulling on the
ring. If valve continues to leak when in the closed
position it should be replaced
check tightness of head bolts. If leak continues
contact authorised service agent.
empty the air tank, remove the non-return valve
cap and clean, or if necessary replace the seal.
tank could rupture or explode. cannot be repaired.
DisCONtiNUe Use iMMeDiAtelY
allow unit to cool for 30 minutes before restarting
reset fuse and restart unit. If repeated tripping
occurs replace the check valve or contact
authorised service agent
Investigate and remedy reason for overload.
reset by pushing button back in (see fig.3d)
contact authorised service agent.
contact authorised service agent.
replace filter element.
contact authorised service agent.
contact authorised service agent.
drain tank after each use