Wiring Diagram - Prochem blazer gt Operating Instructions Manual

Mobile cleaning unit
Hide thumbs Also See for blazer gt:
Table of Contents

Advertisement

ENGINE
OIL PRESSURE
SWITCH
ON ENGINE
USE ENGINE
MOUNTING BOLTS
FOR GROUNDING
WHT
COM
BLK
N.O.
GRN
N.C.
ENGINE SHUTOFF
SWITCH
#61-950621
WASTE TANK
F
M
OPTIONAL EXTERNAL
FUEL PUMP (KUBOTA)
#66-945201
FUEL SOLENOID
M F
REGULATOR
RED 12Ga
RED
F
M
STARTER
RED
4Ga
I
S
SOLENOID
#35-901002
NEG
POS
BATTERY
#36-900056
SHUTDOWN RELAY
#35-900188
WHT
ORG
BLK
GRN
GRN
GRN
BLK
GRN
WHT
ORG
REAR OF
CONNECTORS
F
M
M F
EXTERNAL FUEL
PUMP (AIRTEX)
86317260 BLAZER GT
87
86
87a
85
30
PUMP OUT SWITCH
N.O. CONTACT
BLOCKS
#32-900205
F
M
M
F
FUEL PUMP CORD
#790579

Wiring Diagram

MAIN CIRCUIT BRKR
#33-900161
30
AMP
IGNITION SWITCH
#32-900174
PUMPOUT/AUX
CIRCUIT BRKR
#33-900162
25
AMP
N.O. N.O.
FEMALE CONNECTOR
HOUR METER
#54092
+
-
A B C
FOR PUMPOUT
A B
87