Initial Operational Settings - Prochem blazer gt Operating Instructions Manual

Mobile cleaning unit
Hide thumbs Also See for blazer gt:
Table of Contents

Advertisement

Installation

Initial Operational Settings

NOTE: Due to temperature and altitude changes, the
optimal settings for each truckmount must be
adjusted after installation. Failure to make these
adjustments may lead to poor unit performance and
premature component failure.
Vacuum Pump
The maximum vacuum pressure obtainable at full
throttle should be 13"Hg. If the unit is drawing a
stronger vacuum (at full sealed suction) than 13" Hg,
adjust the vacuum relief spring to 13" Hg.
20
Engine
Set RPM Values as shown below. Refer to Engine
Operation Manual for adjustment instructions.
THROTTLE
Idle
Full
Full
*±50 rpm tolerance
86317260 BLAZER GT
LOAD
None
1400 rpm
13" Hg. Vacuum
3000 rpm
500 psi pressure
None
3200 rpm
RPM*