Menus - Pentair NRG-Temp Manual

Hide thumbs Also See for NRG-Temp:
Table of Contents

Advertisement

Note: this function is only available in EcoH/EcoO
timer programs.
Possible values: ON / OFF
Factory set value: OFF
7.2.2 USER MENU B: "FIRST WARMING"
FUNCTION
When you have installed the heating system in a new
screed, you can use the First Warming function to
help warming up the screed gradually over 21 days.
When the function is active, you cannot use the
NRG-Temp for anything else than for this function.
The display will show the day countdown during the
complete first warming function.
The First Warming function will limit the floor/room
temperature to 20°C.
In case of power interruption, the thermostat will
continue the First Warming function when the power
is restored.
This function can be stopped at any time by setting
the installer menu "B" to OFF.
Possible values: ON / OFF
Factory set value: OFF
7.2.3 USER MENU C: RUNNING TIME
The running time shows how many hours or days,
the underfloor heating has been powered by the
NRG-Temp.
7.2.4 USER MENU D: ADJUSTABLE SWITCHING
HYSTERESIS
The difference between the temperature at which
the thermostat switches OFF and the temperature
at which it switches ON again, is the hysteresis. This
function defines the temperature range between the
switching ON and OFF of the heating in floor sensing
mode.
Possible values: 0.2 to 2.0°C
Factory set value: 0.5°C