SYSTEM CONTROLLER

The system controller maintains communication
between the tank and tankless to effectively control
the tank temperature based on the selected
temperature on the tankless unit.
By reading the tank temperature (J22) and tankless
outlet temperature (J2), the System Controller will
energize (120V) the pump when the tank
temperature drops. When the tank temperature
returns to the selected set temperature the System
Controller will de-energize the pump and remain in
standby until the tank temperature drops again.
ATTENTION
When power is supplied, the System Controller will
maintain pump operation. If system is not in use for
an extended period of time, Disconnect power from
the system.

Checklist for Gas and Electricity

A manual gas control valve is placed in the gas
line to the water heater.
Check the gas lines and connections for leaks.
Confirm that the gas inlet pressure is within
limits.
Confirm that the water heater is rated for the gas
type supplied.
Confirm that the electricity is supplied from 120
VAC, 60 Hz power source and is in a properly
grounded circuit.
Confirm that an extension cord or an adapter plug
has NOT been used with the water heater.
CONTROLLER DIAGNOSTICS
Commercial Hybrid System
PUMP ON (SOLID GREEN LIGHT)
PUMP OFF (NO LIGHT)
NORMAL OPERATION (SLOW PULSE)
THERMISTOR ERROR (RAPID PULSE)