EW30GF65G S
13"
max.
25"
24"
30" Gas Freestanding Range Specifications
Product Weight – 260 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 1.8 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Amps @ 120 Volts = 15 Amps
Always consult local and national electric and gas codes.
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
Do not obstruct flow of combustion air at oven vent nor around base or
beneath lower front panel of range. Range requires fresh air for proper
burner combustion.
Do not install range beneath any downward-blowing, overhead vent
hood or air curtain.
Range ships with 3/4" factory regulator.
Electrolux Major Appliances, N.A.
10200 David Taylor Drive
Charlotte, NC 28262
USA
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
EW30GF65G 06/11
30"min.
30"
min.
C L
18"
30"
min.
23"
11
1
/
"
2
8"
15"
2"
12
1
/
"
2
Shaded area allows for flush installation
with through-the-wall connection of
pipe stub/shutoff valve and rear
wall 120V outlet
Shaded area allows for flush installation
with through-the-floor connection of
pipe stub/shutoff valve
1-877 -4electrolux (1-877 -435-3287)
1-800-265-8352
Minimum
5" clearance
required
to nearest
combustible
wall on
either side
of range
above 36"
18"
height
Wall
min.
36"
stand.
Front
30"
48
1
/
"
2
max.
29
Range is NOT LP Gas convertible — for LP Gas-only model
see EW3LGF65GS.
Floor beneath range MUST be solid and level.
Overhead cabinetry should not exceed a 13" maximum depth.
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
Range can be installed flush to wall with 0" minimum rear clearance.
Minimum 5" clearance required from edge of rangetop to nearest
combustible wall on either side of range above 36" height.
To reduce risk of fire when using overhead cabinetry, install range hood
that projects horizontally a recommended minimum of 5" beyond bottom
of cabinets.
Follow all dimension requirements provided to prevent property damage,
potential fire hazard, and incorrect countertop and cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
Wok Ring – (PN # 318254307).
Simmer Plate – (PN # 318254206).
electroluxappliances.com
electroluxappliances.ca
© 2011 Electrolux Home Products, Inc.
Side
29
1
/
"
4
26
1
/
"
4
25
3
/
"
4
5
46
/
"
8
Gas inlet location
(right bottom rear*)
Power cord location
(left bottom rear*)
*when viewed from front
36"
(Adjustable)
7
/
"
8
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Printed in the U.S.A.