Airflow Direction Control - Panasonic CS-E9GFEW Service Manual

Hide thumbs Also See for CS-E9GFEW:
Table of Contents

Advertisement

Powerful Program
Normal Program
Quiet Program
2. Heating
Note:
a. UP:
• If move from Lo, the fan speed will be shifted to Maximum 1,520 rpm.
• If move from Maximum, the fan speed no change.
• In up zone, 10 rpm is added for every 10s until Maximum 1,520 rpm.
b. DOWN:
• The fan speed will be decreased one step every 10 sec. until Minimum 1,270 rpm.
c. Current Output Fixed:
• Maintain at present fan speed.
d. Instantaneous Maximum:
• Fan speed will be increased to maximum auto fan speed.
e. Temperature in ( ) is for Powerful Mode operation.
9.6.

Airflow Direction Control

9.6.1.
Air Outlet Selection
• When the Air Outlet Selection Switch is turned to ON, air is blown out from both upper and lower air outlet.
• When the Air Outlet Selection Switch is turned to OFF, air is blown out from upper air outlet only.
Model
No. A
CS-E9GFEW
1090
CS-E12GFEW
1090
CS-E18GFEW
1210
CS-E9GFEW
1050
CS-E12GFEW
1050
CS-E18GFEW
1170
CS-E9GFEW
1030
CS-E12GFEW
1030
CS-E18GFEW
1150
(Fig. a)
41
No. B
No. C
1110
1130
1110
1130
1230
1250
1070
1090
1070
1090
1190
1210
1050
1070
1050
1070
1170
1190
(rpm)