Diagnosis
Abnormality / Protection control
display
F91
Refrigeration cycle abnormality
F93
Outdoor compressor abnormal revolution
F95
Cool high pressure protection
F96
IPM (power transistor) overheating
protection
F97
Outdoor compressor overheating
protection
F98
Total running current protection
F99
Outdoor Direct Current (DC) peak
detection
Note:
"O" - Frequency measured and fan speed fixed.
Abnormality
Emergency
Judgement
operation
2 times occurrence
within 20 minutes
4 times occurance
within 20 minutes
4 times occurance
within 20 minutes
4 times occurance
within 10 minutes
3 times occurance
within 20 minutes
7 times occurance
continuously
55
Primary location to verify
• No refrigerant
(3-way valve is closed)
• Compressor
• Outdoor refrigerant circuit
• Excess refrigerant
• Improper heat radiation
• Outdoor PCB
• Insufficient refrigerant
• Compressor
• Excess refrigerant
• Improper heat radiation
• Outdoor PCB
• Compressor
Note