    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ TABLE OF CONTENTS S-UM4JPQ Specifications ............2 Technical Specifications .
  • Page 4: Specifications

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Specifications U n i t e m 7 V E S y s Q - P d o o V R V F X F c I n 1-1 TECHNICAL SPECIFICATIONS...
  • Page 5 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Specifications 1-1 TECHNICAL SPECIFICATIONS S-20UM4JPQ S-25UM4JPQ S-32UM4JPQ S-40UM4JPQ S-50UM4JPQ Standard Standard Accessories Installation and operation manual Accessories Drain hose Washer for hanging bracket Screws Sealing Pads Insulation for fitting Clamp for drain hose...
  • Page 6 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Specifications 1-1 TECHNICAL SPECIFICATIONS S-63UM4JPQ S-80UM4JPQ S-100UM4JPQ S-125UM4JPQ Piping Liquid (OD) Type Flare connection connections Diameter Type Flare connection Diameter 15.9 15.9 15.9 15.9 Drain Diameter VP25 (I.D. 25/O.D. 32) Heat Insulation...
  • Page 7: Electrical Specifications

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Specifications 1-2 ELECTRICAL SPECIFICATIONS S-20UM4JPQ S-25UM4JPQ S-32UM4JPQ S-40UM4JPQ S-50UM4JPQ Power Supply Name Frequency 50/60 Voltage 220-240/220 Current Minimum circuit amps (MCA) Maximum fuse amps (MFA) A Full load amps (FLA) Voltage range...
  • Page 8: Safety Device Settings

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Safety device settings Safety devices S-20UM4 S-25UM4 S-32UM4 S-40UM4 S-50UM4 S-63UM4 S-80UM4 S-100UM -125UM4 PC board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A...
  • Page 9: Options

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Options OPTIONS No. Item Model S-20UM4 S-25UM4 S-32UM4 S-40UM4 S-50UM4 S-63UM4 S-80UM4 S-100UM4 S-125UM4 Decoration panel CZ-06KPU12P Long life replacement filter non-woven type KAFP551K160 Fresh air intake kit (20% fresh air) Chamber type...
  • Page 10: Capacity Tables

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Capacity tables 4 - 1 Cooling capacity tables S-UM4JPQ TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 11 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Capacity tables 4 - 1 Cooling capacity tables S-UM4JPQ TC: Total capacity;kW – SHC: Sensible capacity;kW Indoor air temperature Outdoor Nominal 14.0WB 16.0WB 18.0WB 19.0WB 20.0WB 22.0WB 24.0WB Unit size air temp.
  • Page 12: Heating Capacity Tables

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Capacity tables 4 - 2 Heating capacity tables S-UM4JPQ Indoor air temp.: °CDB Nominal Outdoor air temp Unit size 16.0 18.0 20.0 21.0 22.0 24.0 Capacity °CDB °CWB -19.8 -20.0 -18.8 -19.0...
  • Page 13 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Capacity tables 4 - 2 Heating capacity tables S-UM4JPQ Indoor air temp.: °CDB Outdoor air temp Nominal 16.0 18.0 20.0 21.0 22.0 24.0 Unit size Capacity (°CDB) (°CWB) -19.8 -20.0 -18.8 -19.0...
  • Page 14: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing S-20,12,32,40,50,63UM4JPQ Model 860 - 910 (Ceiling opening) See note 4 FXFQ20-50 6.35 12.7 S-20~50UM4JPQ 300 or less 710 (Suspension position)
  • Page 15 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing S-125UM4JPQ 860 ~ 910 (Ceiling opening) See note 4 300 or less 710 (Suspension position) See note 3 Piping side...
  • Page 16 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing S-80,100UM4JPQ Service acces panel: 450x450 mm or more Note: 3 (Refer to note: 1) Pipe connection side Drain connection side...
  • Page 17 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing S-UM4JPQ Remote control dimensions Receiver installation procedure Transmitting part Receiver Pipe connection side Drain connection side Remote control holder installation procedure...
  • Page 18: Centre Of Gravity

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Dimensional drawing & centre of gravity 5 - 2 Centre of gravity S-UM 4JPQ Models S-20~63UM4JPQ S-80~100UM4JPQ S-125UM4JPQ 4TW28839-2 • VRF Systems • Indoor Units...
  • Page 19: Piping Diagram

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Piping diagram S-UM4JPQ Heat exchanger Refrigerant flow Liquid pipe connection port Cooling Heating Filter Electronic expansion Filter Gas pipe connection port valve Refrigerant pipe connection port diameters Model Liquid S-20,25,32,40,50UM4 12.70 6.35...
  • Page 20: Wiring Diagram

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Wiring diagram 7 - 1 Wiring diagram S-20,25,32,40,50,63,80,100,125UM4JPQ 20~125 Class (22~140-Class) Indoor Receiver/display unit Control box Input from 220~240/220V outside (note 3) ~50/60Hz Central remote control (note 1) Wired remote control...
  • Page 21: Sound Data

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Sound data 8 - 1 Sound pressure spectrum S-25UM4JPQ S-20UM4JPQ Approximate Approximate threshold hearing threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz) Octave band center frequency (Hz)
  • Page 22 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Sound data 8 - 1 Sound pressure spectrum S-50UM4JPQ S-63UM4JPQ (Heating) (cooling) (Heating) Approximate Approximate threshold hearing (cooling) threshold hearing for continuous for continuous noise noise Octave band center frequency (Hz)
  • Page 23 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Sound data 8 - 1 Sound pressure spectrum S-125UM4JPQ Approximate threshold hearing for continuous noise Octave band center frequency (Hz) 4D056875 NOTES Mode Scale Over All (dB): 44.0 34.0 (B, G, N is already rectified) Operating conditons: 50.0...
  • Page 24: Sound Power Spectrum

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Sound data 8 - 2 Sound power spectrum S-32UM4JPQ S-20,25UM4JPQ Octave band center frequency (Hz) Octave band center frequency (Hz) 4TW28837-1 4TW28857-1 NOTES NOTES Data is valid at free field condition.
  • Page 25 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Sound data 8 - 2 Sound power spectrum S-63UM4JPQ S-80UM4JPQ Octave band center frequency (Hz) Octave band center frequency (Hz) 4TW28887-1 4TW28897-1 NOTES NOTES Data is valid at free field condition.
  • Page 26: Air Flow Pattern

    • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-20UM4JPQ Cooling air velocity distribution All round air discharge, air flow direction: horizontal 2.7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 2.7m...
  • Page 27 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-32UM4JPQ Cooling air velocity distribution All round air discharge, air flow direction: horizontal 2.7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 2.7m...
  • Page 28 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-50UM4JPQ Cooling air velocity distribution All round air discharge, air flow direction: horizontal 2.7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 2.7m...
  • Page 29 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-80UM4JPQ Cooling air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 3.2m...
  • Page 30 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-125UM4JPQ Cooling air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 3.2m...
  • Page 31 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-20UM4JPQ Heating air velocity distribution All round air discharge, air flow direction: horizontal 2.7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 2.7m...
  • Page 32 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-32UM4JPQ Heating air velocity distribution All round air discharge, air flow direction: horizontal 2.7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 2.7m...
  • Page 33 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-50UM4JPQ Heating air velocity distribution All round air discharge, air flow direction: horizontal 2.7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 2.7m...
  • Page 34 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-80UM4JPQ Heating air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 3.2m...
  • Page 35 • Indoor Units • FREE AIR CASSETTE • S-UM4JPQ Air flow pattern S-125UM4JPQ Heating air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air velocity distribution All round air discharge, air flow direction: horizontal 3.2m...
  • Page 38 Contact Details: E mail: aircon.info@panasonic.co.uk Telephone: 01344 476599 www.panasonic.co.uk Address: Panasonic Air Conditioning Panasonic House Willoughby Road, Bracknell Berks, RG 12 8FP...