Panasonic CS-RE9NKE Service Manual page 29

Hide thumbs Also See for CS-RE9NKE:
Table of Contents

Advertisement

10.3.4 Connect the cable to the Outdoor Unit
1
Remove the control board cover from the unit by loosening the screw.
2
Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4x
2
1.5mm
flexible cords, type designation 245 IEC 57 or heavier cord.
3
Secure the cable onto the control board with the holder (clamper).
4
Attach the control board cover back to the original position with the screw.
5
For wiring stripping and connection requirement, refer to instruction 10.2.4 of indoor unit.
10.3.5 Pipe Insulation
1
Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please warp the insulated piping end to prevent water from going inside the piping.
2
If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E-FOAM with thickness 6mm or above.
29