OIL BURNER COMPONENTS IDENTIFICATION
1
2
3
4
F3 & F5 BURNER COMPONENTS
1.
Lockout indicator lamp and reset button
2.
Primary control
3.
Primary control sub-base
4.
Pump pressure regulator
5.
Motor
6.
Air adjustment fixing screws
7.
Hydraulic air shutter
8.
Capacitor
9.
Hydraulic Jack (optional)
10. Combustion Head

SERIAL NUMBER IDENTIFICATION

The Riello 15 character serial number, example, 99 A 8511111 00025, is identified as follows:
99 = last two digits of the year of manufacture; A = BI-week of manufacture; 8511111 = burner product code;
00025 = increment of 1 for each burner produced – specific to product code – reset to zero each January 1
Year of manufacture
A) Remove burner and air tube from cartons. Check parts list (inside cover) to ensure all parts are present.
B) Remove burner cover by loosing the three screws securing it. Remove control box and air tube cover (see
page 8).
C) Remove drawer assembly from air tube, insert nozzle and set Turbulator adjustment for specific input
required (see pages 8 & 9), then set aside.
D) Mount air tube to burner chassis (see next page).
C6501010 STANDARD F3-5 MANUAL Rev. 3-2 10/12/2006
RIELLO 40 SERIES
9
8
7
6
5
(99) (A) (811111) (00025)
BI-week of manufacture

INITIAL SET-UP

11
12
13
10
20
19
18
17
11. Semi Flange
12. Turbulator adjustment screw
13. Air tube cover
14. Coil
15. Vacuum gauge port
16. Pressure gauge and bleeder port
17. Return fuel line port
18. Supply fuel line port
19. Capillary tube
20. Mounting flange with gasket