Section 5: Maintenance & Lubrication
Electrical System
Refer to Figure 5-2:
The mower is equipped with a 12 volt negative ground
electrical system powered by a battery located under the
seat. When worn out, replace battery with a
maintenance-free garden mower 12 volt BCI group
UL1HD with 245 cold cranking AMPs (CCA) or U1L-X
with 300 CCA. Follow manufacturer's maintenance,
safety, storing, and charging specifications.
Red Battery
Black Battery
Cable (+)
Cable (-)
Figure 5-2
!
WARNING
Incorrect battery cable connections can damage the mower's
electrical system and cause battery cables to spark. Sparks
around a battery can result in a battery gas explosion and
personal injury.
• Always disconnect negative (black) cable from battery
before disconnecting positive (red) cable.
• Always reconnect positive (red) cable to the battery's
positive (+) post before reconnecting negative (black)
cable to the battery's negative (-) post.
!
WARNING
Keep battery terminals from touching any metal mower parts
when removing or installing battery. Do not allow metal tools
to short between battery terminals and metal mower parts.
Shorts caused by battery terminals or metal tools touching
metal mower components can cause sparks. Sparks can cause
a battery gas explosion which can result in personal injury..
!
WARNING
Acid can cause serious injury to skin and eyes. Avoid skin
contact with battery acid and always wear eye protection
when checking the battery. Flush area with clean water and
call a physician immediately. Acid will also damage clothing.
!
WARNING
Do not overfill battery. Electrolytes may overflow and damage
paint, wiring and structure. Use soap and water when
cleaning the battery. Be careful not to get soap and water into
the battery. Use soda mixed in water to clean corrosion off the
terminals.
12/15/15
Table of Contents
12 Volt Battery
Battery
!
WARNING
Do not allow an open flame near the battery when charging.
Hydrogen gas forms inside the battery. This gas is both toxic
and flammable and may cause an explosion if exposed to a
flame.
Common circuit problems are usually caused by
electrical shorts, corroded or dirty terminals, loose
connections, defective wire insulation, or broken wires.
Switches, solenoids, and ignition components may also
fail, causing a short or open circuit.
Refer to Figure 5-3:
The electrical system is protected by fuses located along
the wire harness beneath the seat.
The fuses are:
Main - 20 Amp, blade type
Clutch - 10 Amp, blade type
33169
Purple Wire Leads
33225
Refer to Figure 5-4:
Remove cover over the fuse to access the fuse.
Before diagnosing the electrical system, use a test light
or voltmeter to check battery voltage. If battery voltage is
satisfactory, check cleanliness and tightness of terminals
and ground connections. A general understanding of
electrical servicing and use of basic test equipment is
necessary for troubleshooting and repair.
Major overhaul or repair of starter motor and charging
system should be performed by trained technicians only.
Uncovered Red
10 Amp Fuse
33226
Fuses Shown With Cover Removed
ZST40 & ZST48 Zero Turn Mowers 357-505M
10 Amp Fuse
20 Amp Fuse
White Wire Leads
Wiring Harness Fuses
Figure 5-3
Uncovered Amber
20 Amp Fuse
Figure 5-4