Gas Pressure - Millivolt; Checking Gas Pressure: Millivolt Control - Monessen Hearth VFI33L(N/P)(V/I) Installation And Operating Instructions Manual

Vfi series vent free gas fireplace
Table of Contents

Advertisement

GAS PRESSURE — MILLIVOLT
CHECKING GAS PRESSURE:
MILLIVOLT CONTROL
Figure 17
The valve regulator controls the burner pressure which
should be checked at the pressure test point.
Turn captured screw counter clockwise two or three turns
and then place tubing to pressure gauge over test point
(Use test point "OUT" closest to control knob). After taking
pressure reading, be sure and turn captured screw clock-
wise firmly to re-seal. Do not over torque. Check for gas
leaks.
Test Port
"OUT"
Figure 17 -
Pressure Test Point Location Millivolt Control
FP2781
millivolt valve
20307670
FP2781
VFI33 Vent Free Gas Fireplace System
13