4

GENERAL INSTRUCTIONS

THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV-
ICED BY A QUALIFIED INSTALLER to conform with local
codes. Installation practices vary from region to region and it
is important to know the specifi cs that apply to your area,
for example: in Massachusetts State:
• The fi replace damper must be removed or welded in the
open
position prior to installation of a fi replace
insert or gas log.
• A carbon monoxide detector is required in all rooms con-
taining
gas fi red appliances
• The appliance off valve must be a "T" handle gas cock.
• The fl exible connector must not be longer than 36 inches.
• The appliance is not approved for installation in a bed-
room or
bathroom unless the unit is a direct vent
sealed combustion
• WARNING: This product must be installed by a licensed
plumber
or gas fi tter when installed within the
commonwealth of
setts.
In absence of local codes, install the BGD36CF and BGD42CF
to the current National Fuel Gas Code, ANSI Z223.1, or the
current CAN/CGA B149, Installation Codes. Mobile home
installation must conform with local codes or in the absence
of local codes, install to the current standard for gas equipped
mobile housing CAN/CSA ZA240 MH Series in Canada or the
Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280, or the Fire Safety Criteria for Manufac-
tured Home Installations, Sites and Communities Standard
ANSI/NFPA 501A in the United States.
The fi replace and its individual shutoff valve must be discon-
nected from the gas supply piping system during any pressure
testing of that system at test pressures in excess of 1/2 psig
(3.5 kPa). The fi replace must be isolated from the gas supply
piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig (3.5 kPa).
When the fi replace is installed directly on carpeting, vinyl tile
or other combustible material other than wood fl ooring, the
fi replace shall be installed on a metal or wood panel extending
the full width and depth.
If the optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with
local codes. In the absence of local codes, use the current
CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or
the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the
United States.

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN
TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!
BGD36CF
Maximum input for the BGD36CF is 17,000 BTU/h for natu-
ral gas and propane. Maximum output for natural gas and
propane is 10,900 BTU/hr at an effi ciency of 64% with the
fan on. The A.F.U.E. (annual fuel utilization effi ciency) rating
is 53% for natural gas and propane.
BGD42CF
Maximum input for the BGD42CF is 24,000 BTU/hr for natu-
ral gas and propane. Maximum output for natural gas and
propane is 16,000 BTU/hr at an effi ciency of 67% with the
fan on. The A.F.U.E. (annual fuel utilization effi ciency) rating
is 61.5% for natural gas and propane.
W415-0566 / E / 09.28.07
When the fi replace is installed at elevations above 4,500ft,
and in the absence of specifi c recommendations from the
local authority having jurisdiction, the certifi ed high altitude
input rating shall be reduced at the rate of 4% for each ad-
ditional 1,000ft.
Minimum inlet gas supply pressure is 4.5 inches water column
for natural gas and 11 inches water column for propane.
Maximum inlet gas pressure is 7 inches water column for
natural gas and 13 inches water column for propane. Manifold
pressure under fl ow conditions is 3.5 inches water column for
natural gas and 10 inches water column for propane.
This fi replace is approved for bathroom, bedroom and bed-
sitting room installations and is suitable for mobile home
installation.
product.
No external electricity (110 volts or 24 volts) is required
for the gas system operation.
Expansion / contraction noises during heating up and
Massachu-
cooling down cycles are normal and are to be expected.
Use only accessories designed for and listed with your
specifi c fi replace.
Provide adequate ventilation air. Provide adequate acces-
sibility clearance for servicing and operating the fi replace.
Never obstruct the front opening of the fi replace.
Objects placed in front of the fi replace must be kept a
minimum of 48" away from the front face of the unit.
Do not use abrasive cleaners to clean plated parts. Buff lightly
with a clean dry cloth. The BGD36CF and BGD42CF are
factory equipped with tempered glass. The glass thickness is
3/16" for both models. Use only replacement glass available
from your Napoleon dealer. DO NOT SUBSTITUTE MATE-
RIALS. Clean the glass after the fi rst 10 hours of operation
with a recommended gas fi replace glass cleaner. Thereafter
clean as required. DO NOT CLEAN GLASS WHEN HOT! If
the glass is not kept clean permanent discolouration and / or
blemishes may result.
CARE OF GLASS, AND PLATED PARTS