AC Applications
Before connecting an appliance or power cord to the generator:
Make sure that it is in good working order. Faulty appliances or
power cords can create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish or
stops suddenly, turn it off immediately. Disconnect the appliance,
and determine whether the problem is the appliance, or if the rated
load capacity of the generator has been exceeded.
Make sure that the electrical rating of the tool or appliance does not
exceed that of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than 30 minutes.
Substantial overloading will open the main breaker. Exceeding the
time limit for maximum power operation or slightly overloading the
generator may not switch the main breaker or DC circuit protector OFF,
but will shorten the service life of the generator.
Limit operation requiring maximum power to 30 minutes.
Maximum power is:
EM3100CX:
EM4500CX·4500CXS:
EM5500CX·5500CXS:
For continuous operation (longer than 30 minutes), do not exceed the
rated power.
Rated power is:
EM3100CX:
EM4500CX·4500CXS:
EM5500CX·5500CXS:
The total power requirements (VA) of all appliances connected must
be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number.
Be sure that all appliances are in good working order before
connecting them to the generator. If an appliance begins to operate
abnormally, becomes sluggish, or stops suddenly, turn off the
generator engine switch immediately. Then disconnect the appliance,
and examine it for signs of malfunction.
28
(B type)
3,100 VA
4,500 VA
5,500 VA
2,800 VA
4,000 VA
5,000 VA