Fibre Channel Pass-Through Module - Dell PowerEdge 1855 Systems User Manual

Hide thumbs Also See for PowerEdge 1855 Systems:
Table of Contents

Advertisement

The PowerConnect 5316M Ethernet switch module is hot-pluggable. To provide connectivity into separate Ethernet networks, two switch modules can be
installed in bays I/O 1 and I/O 2 (see Figure 1-5). I/O bays 3 and 4 require that you install a Gb Ethernet daughtercard in the server module. If redundancy is
not required, you must install the switch module in I/O 1 bay. The switch module has an internal serial port that communicates with the DRAC/MC module.
Table 1-11
lists the indicators on each switch module. For additional information about the PowerConnect 5316M Ethernet switch module, see the
documentation provided with the module.
 Figure 1-12. PowerConnect 5316M Ethernet Switch Module Indicators and Features
 Table 1-11. PowerConnect 5316M Ethernet Switch Module Indicators 
 
Indicator Type
Speed/link activity indicator (bicolor)
 
 
 
 
Duplex mode indicator
 
System/diagnostic indicator
 
 
 

Fibre Channel Pass-Through Module

The Fibre Channel pass-through module provides a bypass connection between the Fibre Channel daughter card in the server module and optical transceivers
for direct connection into a Fibre Channel switch or a storage array. (see Figure 1-13). The Fibre Channel pass-through modules are hot-pluggable. The Fibre
Channel pass-through module in I/O bay 3 connects to port 1 on the optional Fibre Channel daughter card installed in a server module. The Fibre Channel
pass-through module in I/O bay 4 connects to port 2 on the optional Fibre Channel daughter card installed in a server module. To provide redundancy, both
I/O bay 3 and I/O bay 4 must have Fibre Channel pass-through modules installed.
indicators. For additional information on installing or troubleshooting this module, see your Installation and Troubleshooting Guide.
NOTE:
The Fibre Channel pass-through module includes Short Wave Small Form Factor Pluggable (SFP) optical transceivers. To ensure proper
functionality, use only the SFPs supplied with this module.
 Figure 1-13. Fibre Channel Pass-Through Module Indicators and Features
 
 
Activity
Indicator Code
Indicator
Off
Not connected.
Green
The port is connected to a valid link partner on the network.
Green blinking Network data is being sent or received at 1 Gb.
Amber
The port is connected to a valid link partner on the network.
Amber blinking Network data is being sent or received at 10 Mb or 100 Mb.
Green
The port is operating at full duplex mode.
Off
The port is operating at half duplex mode.
Green blinking Module is being powered down by the DRAC/MC controller due to an I/O module mis match.
Off
Module is operating normally.
 
Table 1-12
lists the functionality of the Fibre Channel pass-through module

Advertisement

Table of Contents
loading

Table of Contents