Chapter 3 – AT Commands, S-
Registers and Result Codes
AT Commands
This section summarizes the AT commands for this modem.
Command:
AT
Attention Code
Values:
n/a
Description:
The attention code precedes all command lines except A/, A:, and escape codes.
Command:
RETURN Key
Values:
n/a
Description:
Press the RETURN (ENTER) key to execute most commands.
Command:
A
Force Answer Mode
Values:
n/a
Description:
Answer call before final ring.
Command:
A/
Repeat Last Command
Values:
n/a
Description:
Do not precede this command with AT. Do not press RETURN to execute.
Command:
A:
Continuous Redial
Values:
n/a
Description:
Redial last number until answered (10 redials in DOC modems). Do not precede this command with
AT or press RETURN to execute.
Command:
&An
Answerback
Values:
n = 0 or 1
Default:
0
Description:
&A0
Disables answerback.
&A1
Enables answerback reply to an ID request.
Command:
$An Auto-Reliable Buffering
Values:
n = 0 or 1
Default:
0
Description:
$A0 Discard data received during establishment of a reliable connection.
$A1 Buffer data received during establishment of a reliable connection.
Command:
#An
Auto Speed Detection in Answer Mode
Values:
n = 0–3
Default:
0
Description:
#A0 Start at maximum speed and fall back to a lower speed (26400, 24000, 21600, 19200, 16800,
14400, 12000, 9600, 7200, 4800, 2400, 1200, or 300 bps) as line conditions warrant.
#A1 Maximum speed only.
#A2 Start at maximum speed and fall back decrementally to 4800 bps only.
#A3 Start at 2400 bps and fall back to 1200 to 300 bps only.
Command:
&BSn
Values:
n = 0 or 1
Default:
1
Description:
&BS0 Maximum transmit block size of 64 characters.
&BS1 Maximum transmit block size of 256 characters.
Multi-Tech Systems, Inc. MT2834ZDX User's Guide
Chapter 3 – AT Commands, S-Registers, and Results Codes
Maximum Reliable Block Size
8