SETTING THE SYSTEM

Code + ent or A>
TIMED SET
Code + A
SET
A12345678
Groups
RRR-----
1
SET
A12345678
Groups
SRR-----
ent
TIMED SET
Code + A
SET
A12345678
Groups
RSS-----
A Key
SET
B12345678
Groups
RSS-----
ent
TIMED SET

BEFORE SETTING

Before setting the system ensure all doors and windows are secured
and areas protected by movement detectors are free from obstruction.
ENTERING A PIN - USER LEVEL 1-2
As each digit is entered the keypad responds with a bleep and displays
120
a *. When all the digits are entered, press the ent or A > key to start the
setting routine.
ENTERING A PIN - USER LEVEL 3 - 6
As each digit is entered the keypad responds with a bleep and displays
a *. When all the digits are entered press the A > key to start the setting
routine.

SETTING GROUPS

Where group choice has been assigned to the PIN, select which groups
have to set as part of the setting routine. The set status of each group is
displayed on the keypad screen. Possible status options are :-
R = Ready (Groups is unset, and all zones are closed)
F = Faulted (Group is unset, and at least one zone is open)
S = Set (Group is set)
L = Lockout (Group is locked out, and cannot be unset)
120
Select which groups have to be to set by entering the number of the
group. For example, to set groups 2 and 3 press keys 2 and 3 . The
display changes to indicate the groups selected for setting. Pressing
the ent key starts the setting routine for the specified groups.
The Galaxy 500 has 16 groups whilst the 504 and 512 have 32
groups. If the user has group choice, the available groups will be
displayed at the keypad following a valid code + A >. The groups
will be displayed showing A1 to A8. Use both A > and < B keys to
scroll to the various sets of groups. If the user does not have group
choice, entering the PIN and A > will cause all groups assigned to
the user to set.

EXIT TIME

If all the system zones are closed when the setting routine is started,
60
the display indicates the remaining time, in seconds, to vacate the
premises. Exit the building using the agreed route.
3