o If you have to change the oven power cord, the earthing
(yellow/green) conductor must always be 10 mm longer than the
line conductors.
o Care must be taken to ensure that the temperature of the mains
supply cable does not exceed 50°C.
o If the mains supply cable is damaged, then it must be replaced
by an appropriate replacement.
o Cable type: H05 RRF 3 core x 2.5 mm²
Connecting the mains supply cable
o The mains terminal block is located on the rear of the oven and
the terminals are accessible by removing the terminal block
cover. You should remove the cover screw to access this.
o The cable connections must be made in accordance with the
diagram below:-
o The brass links must be positioned as marked in the diagram
above and once established ALL terminal screws must be
tightened down firmly.
o 1, 2 and 3 are the live
connection, 4 and 5 are
the neutral connection
and the remaining one is
the earth connection.
o The live wire MUST be
placed in connection
number 1.
o The neutral wire MUST be
placed in connection
number 4.
o The earth wire MUST be
placed in the connection
marked with the
symbol.