Connecting the mains supply cable

o The mains terminal block is located on the rear of the oven and
the terminals are accessible by removing the terminal block
cover. You should remove the cover screw to access this.
o The cable connections must be made in accordance with the
diagram below:-
o 1, 2 and 3 are the live connection, 4 and 5 are the neutral
connection and the remaining one is the earth connection.
o The live wire MUST be placed in connection number 1.
The neutral wire MUST be placed in connection number 4.
The earth wire MUST be placed in the connection marked with
the
symbol.
o The brass links must be positioned as marked in the diagram
above and once established ALL terminal screws must be
tightened down firmly.