Saivod Sap 685 Instruction Manual

Saivod Sap 685 Instruction Manual

Portable air conditioner

Advertisement

PORTABLE AIR CONDITIONER
Instruction Manual
☆ Read and retain these instructions for future reference
TC-N028M
TC-N028MH
TC-N028R
TC-N028RH
TC-T028M
TC-T028MH
TC-T028R
TC-T028RH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sap 685 and is the answer not in the manual?

Questions and answers

Summary of Contents for Saivod Sap 685

  • Page 1 PORTABLE AIR CONDITIONER Instruction Manual TC-N028M TC-T028M TC-N028MH TC-T028MH TC-N028R TC-T028R TC-N028RH TC-T028RH ☆ Read and retain these instructions for future reference...
  • Page 2 SPECIFICATION Model no. TC-N028M TC-N028MH TC-T028M TC-T028MH TC-N028R TC-N028RH TC-T028R TC-T028RH Cooling capacity 8500 BTU 8500 BTU 10000 BTU 10000 BTU 2491 W 2491 W 2930 W 2930 W Heating capacity 8500 BTU 10000 BTU 2491 W 2930 W Power/Ampere 1010W/ 4.5A 1010W/ 4.5A 1235W/ 5.5A...
  • Page 3 BEFORE USE GENERAL SAFETY ONLY USE IN THE UPRIGHT POSITION ON A FLAT LEVEL SURFACE AND AT LEAST 50cm FROM ANY OBJECTS (Fig 1 & 4). FIG. 1 DO NOT PLACE OBJECTS ON THE UNIT OR RESTRICT AIR INLET / OUTLET (FIG. CLOSELY SUPERVISE ANY CHILDREN AND PETS WHEN UNIT IS IN USE.
  • Page 4 PARTS Front Back Air filter Control Panel Air inlet Air outlet Exhaust air outlet Carrying handle Caster Cord storage Water stopper / drainage point Accessories 10. Inward adaptor - for insertion over hose and into back of the air conditioner. 11.
  • Page 5 INSTALLATION Installation of the exhaust pipe The unit is a portable air conditioner that may be moved from room to room. 1. Using the foam strips Foam strips FIG.5 Offer foam strips to the window gap and cut to size if necessary. Feed exhaust hose through the foam strip and insert strip into window gaps as shown and slide window across so that foam is held securely.
  • Page 6 Mounting of the exhaust pipe Use only the hose provided and clip exhaust hose and unit adaptor to the back of the air conditioner Avoid kinks and bends FIG.8 in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down.
  • Page 7 Installation of the carbon filter Remove the filter frame from the unit. Separate the filter fixer from the filter frame. Remove the active carbon filter from its plastic bag. Insert the active carbon filter into the filter frame. Fix the filter by reassembling the fixer onto the filter frame.
  • Page 8 OPERATION for mechanical type Cooling only model FIG. 12 Power indicator Fan operating indicator Cooling operating indicator 'Full water' indicator Thermostat Speed switch with options for - LOW FAN, HIGH FAN, LOW COOL, HIGH COOL Timer (1-8 hours) as well as ON/OFF switch Cooling &...
  • Page 9 SPEED Setting function / ventilation speed Cooling only models : HIGH COOL LOW FAN Turn the speed switch to select required setting: LOW FAN, HIGH FAN, LOW COOL, HIGH COOL LOW COOL HIGH FAN FIG.14 SPEED Cooling & heating models : Turn the speed switch to select required HIGH HEAT setting: FAN, LOW COOL, HIGH COOL,...
  • Page 10 OPERATION for electronic type Control panel SPEED MODE DOWN TIMER FIG.17 I/O(power)button 10. Heating mode indicator(for cool & heat Compressor operation indicator model only) Speed(ventilation)button 11. Timer button Low ventilation indicator 12. Timer operation indicator High ventilation indicator 13. `Temperature down` button Mode(function)option button 14.
  • Page 11 Setting ventilation speed 1. Press SPEED button to choose the ventilation speed you need, high or low. The indicator of high or low ventilation will light on at the same time. 2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to the ambient temperature (the related indicators will light on), at this time, the speed switch is invalid.
  • Page 12 DRAINAGE During the process of cooling, some water will be extracted from the air into the unit. If the reservoir is full: a. For mechanical type, the compressor will stop, only the fan to circulate the air. The 'FULL WATER' indicator will light now to remind you. b.
  • Page 13 Please note The drain must be at or below the outlet level. Original drain tube Flashing comp / ‘full water’ Extended indicator will not function in this drain tube (OD:18mm) mode of drainage. 3. If you want to extend the water tube, you can connect it with FIG.23 another tube (OD: 18mm)
  • Page 14 MAINTENANCE Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner clean regularly. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions.
  • Page 15 FAULT CHECK LIST The air conditioner does not run  Is the air conditioner plugged in?  Is there a power failure?  Is the comp / ‘full water’ indicator flashing?  Is the room temperature below the set temperature? ...

Table of Contents

Save PDF