Viessmann Vitopend 100-W Installation And Service Instructions Manual page 39

Table of Contents

Advertisement

Repairs
(cont.)
20
10
8
6
4
2
1
0.8
0.6
0.4
10
30
50
20
40
60
Temperature in °C
1. Temperature limiter:
Check the temperature limiter, if the
burner control unit cannot be reset
after a fault shutdown, although the
boiler water temperature is below
approx. 90 °C.
■ Pull the leads from the sensor.
■ Check the continuity of the temper-
ature limiter with a multimeter.
■ Remove the faulty temperature lim-
iter.
■ Install a new temperature limiter.
4
3
2
1
To reset, briefly turn rotary selector
"tr" clockwise as far as it will go
and then back again. The ignition
process will then be repeated.
70
90
110
80
100 120
5
6
2. Boiler water temperature sensor:
■ Pull the leads from the sensor.
■ Check the sensor resistance and
compare it with the curve.
■ Replace the sensor in the case of
severe deviation.
!
Please note
The boiler water tempera-
ture sensor is immersed in
the heating water (risk of
scalding).
Drain the boiler before
replacing the sensor.
3. Outlet temperature sensor (gas
combi boiler):
■ Pull the leads from the sensor.
■ Check the sensor resistance and
compare it with the curve.
■ Replace the sensor in the case of
severe deviation.
Danger
The outlet temperature sen-
sor is immersed in the DHW
(risk of scalding).
Drain the DHW side of the
boiler before replacing the
sensor.
Troubleshooting
39