  • Page 1 INSTALLATION MANUAL PH, PH1 Hydraulic operator for swing gate...
  • Page 2: Warnings For The Installer

    WARNINGS FOR THE INSTALLER GENERAL SAFETY OBLIGATIONS 1) ATTENTION! To ensure the safety of people, it 14) Make sure that the earthing system is perfectly is important that you read all the following constructed, and connect metal parts of the means instructions.
  • Page 3: Technical Specifications

    HYDRAULIC OPERATOR PH 275 - PH 390 Exploded sight Technical specifications PH 390 PH 275 MODEL Hydraulic lock open open-closed open open-closed closed closed Hydraulic slow down (only closing) Slow travel 390 mm 275 mm Rod stroke (MAX) Rod linear speed Traction / Thrust force to 15 bar Pump flow-rate (l/m) Hydraulic oil...
  • Page 4: Description And Technical Specifications

    HYDRAULIC OPERATOR PH 275 - PH 390 These instructions apply to the following models: PH 275 R, PH 275 BA, PH 275 BC, PH 275 BAC, PH 390 R, PH 390 BA, PH 390 BC, PH 390 BC, PH 390 BAC.
  • Page 5 3.2. HYDRAULIC OPERATOR INSTALLATION Fig. 2 A) Attach the rear mounting on the pillar and follow the signs of Tables A and B, modify, if necessary, the length of the attack (fig. 1). Compliance with the dimensions shown in the above tables to ensure the smooth operation of the automatism.
  • Page 6 PH 275 BAC (lock open / close). In the case of gate leaf length more than m. 2.3, it is recommend the use of hydraulic operator PH 275 R or PH 390 R (reversible). The mounting dimensions of the hydraulic operator is detected by the following Table C.
  • Page 7: Maintenance And Repair

    4. ANTI-CRUSHING CONTROL SYSTEM 5. MANUAL OPERATION AND RESET - FINAL OPERATIONS - TEST AUTOMATION 5.1. MANUAL OPERATION 4.1. SETTING ANTI-TRAP (fig.9) In case is necessary to manually operate the gate for absence The hydraulic operators PH, they have a security anti-trap for of electric tide or damage of the automation, you must be acted to control the hydraulic operator force, in the presence of an on the device of unblocking as it follows:...
  • Page 8: General Safety

    - Don’t stop and not to allow children, people or things to stop in PH 275 R - PH 275 BA - PH 275 BC - PH 275 BAC PH 390 R the proximities of the automation, still avoiding it during - PH 390 BA - PH 390 BC - PH 390 BAC.