Download Print this page

Curtis TLCG1509S Service Manual

Advertisement

Quick Links

Service Manual TLCG1509S Milano 1.5 Gallon Server
BREWING INTO SERVERS
Use only coffee or water in the thermoserver. Do not use the thermoserver to dispense any other beverage.
Preheating is recommended.
1.
Place a clean and empty server centered under the brewcone of the Milano brewer.
2.
Make sure the LCD screen reads READY TO BREW.
3.
Fill brewcone with the correct measure of ground coffee for the volume of coffee you wish to brew.
4.
Press the desired brew button on the brewer control panel.
5.
Allow coffee in the brewcone to drip out completely before removing the thermoserver.
WARNING – SERVERS MAY BE HEAVY WHEN FILLED.
CARE MUST BE TAKEN WHEN TRANSPORTING TO AVOID DROPPING OR SPILLING.
SERVICING
1. Completely drain the unit of any coffee.
2. Allow server to cool.
3. Unscrew and remove the lid and tube assembly.
REPLACING THE GAUGE GLASS
The gauge glass can be removed for maintenance and cleaning.
1. Remove the gauge glass shield by pulling upward.
2. Carefully, pull up on the gauge glass to free it from the silicone base gasket that sits on the faucet assembly.
3. Pull off the silicone cap on top of the tube.
4. Scrub inside the glass with a tube cleaning brush and mild detergent solution. Inspect the glass tube
for cracks or chips.
WARNING – If gauge glass was broken, carefully remove all traces of glass. Brush out the silicone
base. From inside the liner, brush out the faucet shank. Run clear water through the shank to make
sure any glass shards have been washed from the faucet and base.
5. Check the top cap and bottom silicone base. Clean these fittings, making sure they are not leaking.
Replace if necessary.
6. Once clean and dry, assemble the parts that were removed for maintenance.
SERVICING THE FAUCET
The faucet will require periodic cleaning and maintenance.
2. Disassemble the faucet. Unscrew the bonnet from the body of the faucet.
3. Remove the faucet handle by pressing inward on the seat cup (see illustration, right) then unhooking
the handle from the center shaft.
4. The seat cup, center shaft and spring will now separate from the bonnet.
5. You may now clean the parts of the faucet (illustration, bottom right). Check the seat cup for tearing or
splitting. Make sure that the faucet spring is free of corrosion. Replace these items if necessary.
Cleaning and Sanitizing Instructions for TLCG15
These cleaning and sanitizing instructions are only a guide line to be used for the cleaning and sanitizing of
the TLCG15. Your current in-house cleaning and sanitizing methods may be just as effective.
For cleaning and sanitizing of the TLCG15, the three sink method is recommended. This method consists of a sink of water filled
with a detergent and water solution, a fresh water rinse, and a sink filled with an aqueous sanitizing solution.
Immersion of parts in commercial BarTabs/Sani-Tabs sanitizing solution is recommended. The solution must be warm (75°F.) Let the
parts soak at least one minute.
W
C
ilbur
urtis
FOR THE LATEST SPECIFICATION INFORMATION GO TO
WWW.WILBURCURTIS.COM
C
, i
ompany
.
nC
HANDLE
BONNET
SPRING
SHAFT
SEAT CUP
Continued on page 2...
1

Advertisement

loading

Summary of Contents for Curtis TLCG1509S

  • Page 1 Service Manual TLCG1509S Milano 1.5 Gallon Server BREWING INTO SERVERS Use only coffee or water in the thermoserver. Do not use the thermoserver to dispense any other beverage. Preheating is recommended. Place a clean and empty server centered under the brewcone of the Milano brewer.
  • Page 2 Use a tube brush soaked in cleaning solution to clean the faucet shank. Push the brush into the center tube of the faucet shank and scrub it. Rinse by pouring water from inside the unit, allowing rinse water to flow into a sink until water runs clear. 5. When all pieces are completely dry reassemble for use. TLCG1509S Milano 1.5 Gallon Server Rough-In Drawing 9” (22.9 cm) 22.5”...
  • Page 3: Replacement Parts List

    REPLACEMENT PARTS LIST Index Index Part Part Description Description Nº Nº Nº Nº WC-75279 LID ASSEMBLY WC-1856 FAUCET, ASSY LCKNG HNDL WC-75280 DRIP TRAY ASSEMBLY WC-37275 KIT, FAUCET LOCKING WC-36076 BRUSH, GAUGE GLASS WC-75286 COVER, SIGHT GLASS ASSY WC-56003 COVER, SIGHT GLASS MILANO WC-53110 TUBE, SILICONE ADAPTER WC-43078...
  • Page 4 Curtis equipment that have not been purchased from the Wilbur Curtis Company, Inc. The Wilbur Curtis Company will not accept any responsibility if the following conditions are not met. The warranty does not cover and is void under the following circumstances: 1) Improper operation of equipment: The equipment must be used for its designed and intended purpose and function.