Electrical Connection - Scheppach ha 1000 Instruction Manual

Dust extractor
Table of Contents

Advertisement

Fig. 5
Now plug the filter cartridge 1 onto the motor casing 2.
Place the entire motor casing on the container and secure
with the locking strap.
Mounting the exhaust hose, fig. 6 (earthing)
Remove the plastic sheathing from one end of the helix
flex, so that the blank lead A becomes visible (appr. 2
cm).
Fasten the clamps (B) to the bare wire (A).
Mount exhaust hose C to the hose fitting on the casing us-
ing hose clamp D.
Fig. 7
Attach the other end of the exhaust hose using a hose
clamp and hose coupling E.
m Electrical Connection
Connecting the electrical equipment, or any repair work,
may only be carried out by a qualified electrician.
The built-in electric motor is already connected and ready
for operation. The connection conforms to the relevant
VDE (German Association for Electrical, Electronic and
Information Technologies) and DIN (German Institute for
Standardization) regulations.
The connection to the mains supply made by the custom-
er, as well as the extension cord used, must comply with
these regulations.
Important Notes
Faulty power cords
Power cords often suffer insulation damage.
Causes are:
• Pinching when power cords are routed through windows
or door cracks.
• Bending due to improper attachment or routing of the
power cords.
• Cuts due to driving over the power cords.
• Insulation damage caused by yanking the mains plug
out of the power outlet.
• Cracks in the insulation due to ageing.
Such faulty power cords must not be used and are a danger
to life because of the damaged insulation!
Inspect the power cords for damage on a regular basis.
Make sure that during this inspection the power cord is not
connected to the mains supply.
The power cords must comply with the applicable VDE
(German Association for Electrical, Electronic and In-
formation Technologies) and DIN (German Institute for
Standardization) regulations. Only use power cords marked
as H 07 RN.
A type identification printed on the power cords is pre-
scribed.
AC Motor
• The power supply must be 230–240 V/50 Hz.
• Extension cords must have a minimum conductor cross
section of 1.0 square millimetres.
• The connection to the power supply must be protected
with a 16 A (delayed-action) fuse/ circuit breaker.
When you have questions, please include the following de-
tails:
• Motor manufacturer
• Type of current
• The details from the type plate of the machine
• The details from the type plate of the switch
Always send back the whole drive unit including the switch,
when you return the motor.