Sanitizing - Stoelting A118 Operator's Manual

Frozen beverage dispensers
Table of Contents

Advertisement

Fit bushing onto auger then
Fit bushing onto auger then
align bushing with door cutout.
align bushing with door cutout.
Figure 3-6 Align Square Bushing
C.
Lubricate the drive end of the auger with a small
amount of spline lubricant. A small container of
lubricant is shipped with the machine.
D.
Install the two plastic blades onto the auger and
insert the auger into the freezing cylinder. Position
the auger with the blade arms vertical and the
drive end inserted just enough to engage the
drive.
E.
Apply a thin layer of sanitary lubricant to the
inside and back (side facing auger) of the square
auger support bushing. Install the bushing onto
the auger.
F.
Fit the front door o-ring into the groove on the
rear of the front door.
G.
Align square cutout on the front door with the
auger support bushing. Seat the bushing into the
front door then place the door onto the mounting
studs.
H.
Secure the front door to the machine by placing
the knobs on the studs and tightening until finger
tight. Tighten in a crisscross pattern. Do not
overtighten. Proper o-ring seal can be observed
through the transparent front door.
I.
Place the o-ring onto the spigot housing and
lubricate the o-ring with sanitary lubricant. Install
the housing into the front door.
Insert spigot housing into
Insert spigot housing into
door and rotate 90º
door and rotate 90º
Figure 3-7 Install Spigot Housing
Owner's Manual #513691
Handle
Handle
Retaining
Retaining
Pin
Pin
Spigot Lock Clip
Spigot Lock Clip
Figure 3-8 Spigot Assembly
J.
Assemble the spigot assembly.
1. Install the spigot lock clip into the retaining
cap.
2. Place the o-rings onto the retaining cap
and valve plug. Lubricate the o-rings with a
generous amount of sanitary lubricant.
3. Put the spring and retaining cap onto the valve
plug.
4. Press the retaining cap against the plug so
that the retaining pin can be installed.
5. Install the pin onto the shaft and turn it 90°.
K.
Install the assembly into the spigot housing and
rotate the assembly clockwise 90° to secure it.
L.
Install the spigot handle onto the spigot assembly.
1. Make sure the handle retaining pin is vertical.
Align the handle onto the pins in the spigot
housing.
2. Pull and rotate the retaining pin so that it locks
the handle in place.

3.8 SANITIZING

Sanitizing must be done after the machine is cleaned and
just before the hopper is filled with mix. Sanitizing the night
before is not effective. However, you should always clean
the machine and parts after each use.
The United States Department of Agriculture and
the Food and Drug Administration require that all
cleaning and sanitizing solutions used with food
processing equipment be certified for this use.
When sanitizing the machine, refer to local sanitary regu-
lations for applicable codes and recommended sanitizing
products and procedures. The frequency of sanitizing
must comply with local health regulations.
Mix sanitizer according to manufacturer's instructions to
provide a 100 parts per million (ppm) strength solution.
Mix sanitizer in quantities of no less than 2 gallons (7.5
liters) of 90° to 110°F (32° to 43°C) water. Allow sanitizer
to contact the surfaces to be sanitized for 5 minutes.
Any sanitizer must be used only in accordance with the
manufacturer's instructions.
8
Spring
Spring
Valve Plug
Valve Plug
Retaining Cap
Retaining Cap
A118/D118 Model Machines

Advertisement

Table of Contents
loading

This manual is also suitable for:

D118

Table of Contents