Savannah Heating BL21 Installation And Operating Instructions Manual page 29

Elite linear fireplace 21,000 btu
Table of Contents

Advertisement

USE OF SEALANT
Sealant is required on vent system joints, except Metal-Fab Sure-Seal direct vent system joints
(figure 7). On longer vent runs, especially vertical runs, sealant will ensure that the combustion air
enters from outdoors, and not through the vent joints. Use high temperature sealant, available from
local suppliers, on the inner pipe joint, applying the sealant around the outside of the male part of the
vent. A bead of silicone should be used on the outside of the joint after assembly to seal the supply
air. If the venting is disconnected for servicing, be sure to follow above instructions for resealing
venting when reconnecting to system.
A minimum clearance to combustibles must be maintained around the vent pipe of 1"
Un dégagement minimum aux matériaux combustibles doit être maintenu autour du
tuyau de 1 "sur toutes les canalisations horizontales et verticales fonctionne
FIGURE 7
VENT RESTRICTOR INSTALLATION
VENT RESTRICTOR
To fasten the Restrictor Plate to the ceiling of the firebox:
1/. Remove the 2 screws that are in place
2/. Align holes in the Restrictor that match the required degree of restriction
3/. Fasten Restrictor Plate back in place.
on all horizontal and vertical pipe runs
Vent Configuration Restrictor Size
SCREW HERE
SCREW HERE
Apply RTV high temperature
sealant around male pipe.
60%
40%
20%
60%
60%
60%
40%
40%
40%
20%
20%
20%
Page 29 of 57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Blst21

Table of Contents