Savannah Heating BL21 Installation And Operating Instructions Manual

Elite linear fireplace 21,000 btu

Advertisement

ELITE LINEAR FIREPLACE
21,000 BTU
Natural Gas & Propane
Installation and Operating Instructions
MODEL: BL21
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance
Do not touch any electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbour's phone. Follow gas supplier's
instructions
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or gas
supplier.
WARNING: Improper installation, adjustment, alteration, services or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
PLEASE READ THIS MANUAL BEFORE
INSTALLING OR USING THIS APPLIANCE.
SAVE THIS MANUAL FOR FUTURE
REFERENCE.
A BARRIER DESIGNED TO REDUCE THE RISK OF
BURNS FROM THE HOT VIEWING GLASS IS PROVIDED
WITH THIS APPLIANCE AND SHALL BE INSTALLED.
CLIENT # LC773211
WARNING
any other appliance.
Page 1 of 57

Advertisement

Table of Contents
loading

Summary of Contents for Savannah Heating BL21

  • Page 1 ELITE LINEAR FIREPLACE 21,000 BTU Natural Gas & Propane Installation and Operating Instructions MODEL: BL21 CLIENT # LC773211 WARNING IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
  • Page 2 DV ELITE FOYER LINEAR GAZ NATUREL ET PROPANE Manuel D’installation et Guide de l’utilisateur CLIENT # LC773211 AVERTISSEMENT ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉES DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU D'EXPLOSION OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
  • Page 3: Table Of Contents

    Table of Contents IMPORTANT SAFETY INFORMATION …………………………………………………………….. 4 – 5 INTRODUCTION ........................Specifications, Appliance Dimensions & Installation Codes ......... 6 - 7 Features, Remote Control Functions ..............8 - 10 Intended Use ......................11 General Safety ....................11 - 12 OPERATION ...........................
  • Page 4: Important Safety Information

    WARNING  Read this owner’s manual carefully and completely before trying to assemble, operate or service this fireplace. Follow instructions for proper installation  Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
  • Page 5 WARNING AVERTISSEMENT Ne pas utiliser cet appareil s’il a été plongé, Do not use this appliance if any part has meme partiellement, dans l’eau. Appeler un been under water. Immediately call a technician qualifié pour inspecter l’appareil et qualified service technician to inspect the appliance and to replace any part of the remplacer toute partie du système de control system and any gas control which...
  • Page 6: Introduction

    1.0 INTRODUCTION 1.1 SPECIFICATIONS TABLE 1 ITEM NATURAL GAS (NG) PROPANE (LP) INPUT: Hi 21,000 Btu/hr (6.15 kW) 20,750 Btu/hr (6.08 kW) INPUT: Lo 13,000 Btu/hr (3.81 kW) 13,000 Btu/hr (3.81 kW) MANIFOLD PRESSURE: Hi 3.5” w.c. (0.87 kPa) 10.0” w.c. (2.49 kPa) COLLECTEUR DE PRESSION: FORT MANIFOLD PRESSURE: Lo...
  • Page 7 APPLIANCE DIMENSIONS Figure 1 34.133” 17.134” 15.50” 8.872” 16.000” 29.565” 1.500” 27.503” 13.040” 7.400” 38.000” 14.416” INSTALLATION CODES This appliance is a Direct Vent appliance which draws all combustion air from outside the building through an intake vent pipe. Installation must conform to local codes. In the absence of local codes, installation must conform to the National Fuel Gas Code ANSI Z223.1/NFPA 54, or the current Natural Gas and Propane Installation Code CSA B149.1.
  • Page 8: Features, Remote Control Functions

    1.2 FEATURES Ignition system: Standing pilot ignition system with thermopile and thermocouple flame detection and piezo igniter. Fan control * Optional * Variable speed control: For units equipped with a fan control, the knob controls the fan speed, turning the knob counter-clockwise turns it to the “Off”...
  • Page 9 Program Mode The Program function is controlled by the PROG/TIME button. The control may be programmed for up to two settings for weekdays and two settings for weekends. The control is preset to factory settings. When the Program Mode is activated, the unit will automatically be operating in the Thermostat Mode. The unit will turn on or off based upon room and set temperature.
  • Page 10 Fan Control The unit must be ON to operate the Fan. The Fan will turn on after 5 minutes of operation. Once the Fan comes on, it can be controlled using the FAN button. Press the FAN button, and the fan icon and speed will appear on the LCD screen. Press the UP or DOWN button to control the fan speed (0-6).
  • Page 11: Intended Use

    1.3 INTENDED USE / USAGE PROPOSÉ This appliance is intended to be used as a zero clearance fireplace. This unit is certified for installation in a bedroom or a bed sitting room where the maximum input is within 50 cubic feet per 1000 Btu/hr, (i.e. 900 cubic feet for E unit & 1600 cubic feet for H unit).
  • Page 12 IMPORTANT PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. It is not unusual for gas fireplaces to give off some odors the first time they are burned. This is due to the oils and sealants in the manufacturing process.
  • Page 13: Operation

    2.0 OPERATION LIGHTING INSTRUCTIONS - for Intermittent Pilot FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. BEFORE LIGHTING smell all around the appliance area for gas.
  • Page 14 INSTRUCTIONS D'ALLUMAGE - Pilote intermittent POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT: Quiconque ne respecte pas à la letter les instructions dans la présente notice risqué de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. Cet appareil est équipé...
  • Page 15: Heat Output Adjustment

    2.2 HEAT OUTPUT ADJUSTMENT The valve supplied with the appliance has a HI/LO knob to control the heat output and flame height (see valve diagram in Lighting Instructions, section 2.1). 2.3 FAN OPERATION (optional) For units equipped with a fan control knob, the knob is located in the valve control compartment and may be adjusted to the following settings: OFF: Turn the control fully counter-clockwise until the switch operates.
  • Page 16: Installation

    3.0 INSTALLATION 3.1 INSTALLATION & SAFETY NOTES / NOTES D'INSTALLATION ET DE SECURITE Read all instructions before starting installation and follow them carefully during installation to ensure maximum benefit and safety. Failure to follow these instructions will void your warranty and may present a fire hazard.
  • Page 17: Minimum Clearances & Non Combustible Material Requirements

    3.3.1 MINIMUM CLEARANCES / DÉGAGEMENTS 36.000” 48.000” 33.500” 447.00 7.000 0.000 38.000 Framing Dimensions 38” wide x 33.5” high x 15.5” deep 2.000 2.000 15.500 6.000 MINIMUM CLEARANCES TO COMBUSTIBLES A = 48” TO INTERNAL CEILING (combustible material) B = 2” TO INTERNAL SIDE COMBUSTIBLES C = 15.5”...
  • Page 18 Mantle Minimum distance 40.000 from bottom of fireplace to mantel 12.000 Clearances are in accordance with local installation codes and the requirements of the gas supplier. **The mantel placement chart on this page illustrates the allowable mantel sizes and placements. The 45 degree angle can be used to determine the allowable mantel size based on the elevation above the units upper trim.
  • Page 19 Heat Baffle 8” x 34.5” fixed to non- combustible board by Non-combustible manufacturer (see board supplied by diagram next page for manufacturer side view) 15.500” 8.052” 33.500” 34.500” 26.355” 36.000” 38.000” NOTE STUD MUST BE INSTALLED ON EDGE AS SHOWN IN THIS DIAGRAM The closest combustible material above the fireplace must be a minimum of 33.50”...
  • Page 20: Gas Line Installation

    NON COMBUSTIBLE MATERIAL/ MATIERE NON COMBUSTIBLES Non-combustible material will be supplied by the manufacturer. This must be installed on top of the fireplace as shown above to meet installation codes. Heat baffle will be installed to non-combustible board by manufacturer. Matériaux non combustibles seront fournis par le fabricant.
  • Page 21: Thermostat,Wall Switch Or Digital On/Off Remote

    Upon initial firing check manifold pressure at pressure tap located on the front control panel (see Lighting Instructions in section 2.1 ). Lors de la première vérification de la pression de tir collecteur à la pression du robinet situé sur le panneau de commande avant (voir les Consignes d'allumage à la section 2.1). WARNING AVERTISSEMENT DO NOT USE AN OPEN FLAME TO TEST FOR GAS LEAKS...
  • Page 22 TABLE 1 THERMOSTAT WIRE INFORMATION WIRE SIZE MAX. WIRE LENGTH 12.2 19.5 30.5 After the unit is installed and the gas line hooked up, crimp a fork connector to each wire and attach them to the TH/TP and TH screws located on the valve. Après que l'unité...
  • Page 23: Direct Vent Information

    3.3.4 DIRECT VENT INFORMATION / DIRECT VENT D'INFORMATION The unit must be connected to listed 2-ply aluminium venting, 4” flex vent on the exhaust side and listed 7” flex vent on the air intake side or can be used with Security Venting, Dura-Vent 4” x 6-5/8” with the use of Dura-Vent adapters part #’s 0924N3 &...
  • Page 24 Figure 6 Dura-Vent or Selkirk Direct-Temp Venting The minimum vent system for horizontal termination must consist of: Dura-Vent adapter Part # 0924N3 directly on top of unit or Selkirk Part #1604247B 12” (305mm) vertical length of vent 90 degree elbow 12"...
  • Page 25 Security Venting The minimum vent system for horizontal termination must consist of: Dura-Vent adapter Part # 0924N3 directly on top of unit 12” (305mm) vertical length of vent 90 degree elbow 12" (305 mm) horizontal length of vent Wall thimble part #IMC1082A Horizontal termination cap SV4CHC The maximum horizontal vent system consists of:...
  • Page 26 2-Ply Aluminum Flex Vent The minimum vent system for horizontal termination must consist of: 12” (305 mm) vertical length (measured to center of vent pipe) with a 90 degree bend and a 12” (305 mm) horizontal length (measured from center of vent pipe) Wall thimble part# IMC1082A Horizontal termination cap part # IMC1070A or IMC1070B The maximum horizontal vent system...
  • Page 27 VENT TABLE (All values are in feet) 1 & 2 2 ½ 5 ½ 4 ½ 8 ½ 7 ½ 11 ½ 11 ½ 11 ½ 11 ½ 11 ½ 11 ½ V = 34 Feet Max. = 11 ½ Feet Max NOTE: All vent dimensions are measured from the appliance surface where the vent connects to the point where exhaust gases exit the termination.
  • Page 28 34’ 20’ 12” Minimum 24” Maximum (Example: Where A---A = Vertical @ 2 ½’ B---B = Horizontal @ 5’) Page 28 of 57...
  • Page 29 USE OF SEALANT Sealant is required on vent system joints, except Metal-Fab Sure-Seal direct vent system joints (figure 7). On longer vent runs, especially vertical runs, sealant will ensure that the combustion air enters from outdoors, and not through the vent joints. Use high temperature sealant, available from local suppliers, on the inner pipe joint, applying the sealant around the outside of the male part of the vent.
  • Page 30 VENT RESTRICTOR INSTALLATION (continued) The restrictors are installed by removing the 2 screws on the ceiling of the firebox, place the desired restrictor in place and use the screws to fasten the restrictor to the firebox. You must first remove the firebox baffle (4 screws) before installing the desired restrictor.
  • Page 31 48.000” 15.500” Safety Cage Mark a 11” x 11” square around the center mark (inside dimensions). Cut and frame the exterior wall to accept the wall thimble. Install the wall thimble, on the inside of the exterior wall, shield using wood screws. Attach the venting to the termination using sheet metal screws, for Z-Flex installations an Inca Metal Cutting’s termination part # IMC1070A or IMC1070B shall be used and when using Simpson Dura-Vent or Security Venting a Simpson Dura-Vent termination part # P574 shall be used.
  • Page 32 Vertical Installations Always maintain a 1” clearance around the vent pipe (vertical) and 1” clearance horizontal, when passing through ceilings, walls, roofs, enclosures, attic rafter or any combustible surfaces. DO NOT PACK AIR SPACES WITH INSULATION NE PAS PACK ESPACES D'AIR AVEC ISOLATION When passing through a flat ceiling install a Box/Wall thimble.
  • Page 33 Termination above Roof Consult local codes for minimum vent cap height above the roof (X), vent must be a minimum of 2’ from any wall. To prevent water seepage; install the flashing with upper portion under the roofing material and the lower portion over the roofing material.
  • Page 34 In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code In accordance with the current ANSI Z223.1 / NFPA 54, National Fuel Gas Code † A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings ‡...
  • Page 35: Glass Installation

    3.3.5 Glass Installation / Installation de verre Burn medium positions are critical to the safe and clean operation of this appliance. Never add any other material into the firebox. Use only with burn medium supplied with this unit. Burn positions moyennes sont critiques pour le fonctionnement sûr et propre de cet appareil.
  • Page 36: Door Installation And Safety Screen

    3.3.6 Door Installation Do not operate this appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.  For use with glass doors certified with the appliance only ...
  • Page 37: Initial Firing

    3.3.7 INITIAL FIRING When lit for the first few times, the appliance may emit an odor resulting from evaporation of paint and lubricants used in the manufacturing process. Open a door or window for ventilation. Anyone with a respiratory condition may need to leave the room during the initial firings. It is normal for the appliance to expand and contract while it heats up or cools down whether this is from a cold start or a steady-state condition where the fan has come on or off.
  • Page 38: Altitude Adjustment

    Set Screw Air tube and Air shutter shown removed for clarity purposes only. 6/. Reassemble the fireplace in reverse order from 3 through 2. / Remonter la cheminée dans l'ordre inverse de 3 à 2. 7/. Turn on the gas. / Allumez le gaz. PARTS REQUIRING ADJUSTMENT DURING OPERATION MAY BE HOT.
  • Page 39: Fan Access

    3.3.11 FAN ACCESSIBILITY / FAN ACCESSIBILITÉ TURN THE MAIN GAS & POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED, CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE, VOTRE FOURNISSEUR DE GAZ 1/.
  • Page 40 5/. Once removed from the wall the fan will slide out through the opening. / Une fois retiré du mur que les fan vont glisser par l'ouverture. 6/. To replace fan and reassemble the fireplace go in reverse order from steps 5 through 1. / Pour remplacer les fan et montons la cheminée aller dans l'ordre inverse des étapes 5 à...
  • Page 41: Gas Valve Access

    3.3.12 GAS VALVE ACCESSIBILITY / ACCESSIBILITÉ ROBINET DE GAZ. TURN THE MAIN GAS & POWER OFF TO FIREPLACE BEFORE COMMENCING ANY WORK ON THE FIREPLACE THIS SHOULD BE DONE BY A LICENSED, CERTIFIED GAS INSTALLER TURN LE PRINCIPAL GAZ ET MISE HORS TENSION AU FOYER AVANT DE COMMENCER TOUT TRAVAIL SUR LA FOYER CELA DEVRAIT ETRE FAIT PAR UNE LICENCE, VOTRE FOURNISSEUR DE GAZ 1/.
  • Page 42: Optional Surround Bracket Placement

    3.3.13 OPTIONAL SURROUND BRACKET PLACEMENT 4.0 MAINTENANCE 4.1 MAINTENANCE SAFETY WARNING AVERTISSEMENT TURN OFF THE GAS TO THE MAIN BURNER AND ALLOW THE HEATER TO COOL FOR UP TO 30 MINUTES BEFORE SERVICING. COUPEZ LE GAZ AU BRÛLEUR PRINCIPAL ET LAISSEZ L'APPAREIL REFROIDIR PENDANT JUSQU'À 30 MINUTES AVANT L'ENTRETIEN.
  • Page 43: Glass Cleaning

    4.3 GLASS CLEANING The inside of the glass may require periodic cleaning to remove deposits left from impurities in the gas and combustion air. For best results, use a ceramic glass cleaner or polish. Use a cleaner suitable for ceramic glass ®...
  • Page 44: Trouble Shooting

    5.0 TROUBLE SHOOTING - INTERMITTENT PILOT SYMPTOM CORRECTIVE ACTION POSSIBLE CAUSE A. No spark at electrode (weak or not heat source for pilot ignition) I. Pilot will not light after repeated triggering of the remote control – intermittent pilot 1. Align the electrode with 1/8” (3mm) gap to 1.
  • Page 45 4. Defective wiring or connections 2. Conduct a test with a jumper wire and repair as required 5. Defective Valve 3. Contact service technician Soot deposits 1. Air inlet blocked or restricted Clean air inlets 2. Vent system is restricted or 2.
  • Page 46: Replacement Parts

    6.0 REPLACEMENT PARTS When requesting service or replacement parts for your unit, please provide model name and serial number. All parts listed below may be ordered from an authorized dealer. Description Part# Certification Door IMC512 Burner IMC514 IMC1057A CSA / UL Door Glass IMC528 ASTM C1048...
  • Page 47: Warranty

    7.0 INCA METAL CUTTING’S WARRANTY PROTECTION FOR ALL INCA METAL CUTTING GAS FIREPLACE PRODUCTS Inca Metal Cutting’s products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak tested and test fired at a quality control test station.
  • Page 48: Warranty

    CONDITIONS AND LIMITATIONS (continued) Notwithstanding any provisions contained in this warranty, Inca Metal Cutting’s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental, consequential or indirect damages. This warranty defines the obligations and liability of Inca Metal Cutting with respect to the Inca Metal Cutting gas fireplace and any other warranties expressed or implied with respect to this product, its components or accessories are excluded.
  • Page 49 CONDITIONS ET LIMITES (SUITE) doit être faite en conformité avec les instructions d'installation incluses avec le produit et toutes les capacités locales et nationales et de prévention des incend Cette garantie limitée ne couvre pas les dommages causés par une mauvaise utilisation, manque d'entretien, accident, des altérations, des abus ou de négligence.
  • Page 50: Label Information

    8.0 LABEL INFORMATION Page 50 of 57...
  • Page 51: Label Information

    8.0 LABEL INFORMATION (continued) Sections of the venting system have not been installed. WARNING – Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer’s instructions. Des sections du système d’évacuation n’ont pas été installées. AVERTISSEMENT - Ne pas utiliser l’appareil tant que toutes les sections n’ont pas été...
  • Page 52: Appendix A (Intermittent Pilot & Valve Kit)

    APPENDIX A (AMERICAN FLAME VALVE INFORMATION) Page 52 of 57...
  • Page 53 APPENDIX A (Continued) Page 53 of 57...
  • Page 54 APPENDIX A (Continued) Special Features on the AF-4000 System The AF-4000 Module can be powered two different ways. The first is a standard 110 volt AC to 6.0 volt DC adaptor. This adapter is connected to the AF-4000 Module by connecting the two 1/4” female terminals from the adapter to the two 1/4” male terminals, located on the AF-4000 Module , marked POWER.
  • Page 55: Appendix B (Ng-Lp Conversion Kits)

    APPENDIX A (Continued) AF-4000 Wiring Diagram APPENDIX B (NG – LP CONVERSION KITS) This kit will convert the fireplace to Natural Gas / Propane (as applicable). / Ce kit vous permet de convertir la cheminée au gaz naturel / propane (le cas échéant). The Elite models are designed to burn either natural gas or propane.
  • Page 56 8). Apply BL21-LP label plate over existing natural gas label plate and notify Savannah Heating of the serial numbers of both plates. (Original plate and replacement plate) / Appliquer plaque d'étiquette BL21-LP-dessus de la plaque d'étiquettes existante de gaz naturel et de notifier savane chauffage des numéros de série des deux...
  • Page 57 CONVERSION INSTALLATION / INSTALLATION DE CONVERSION ORIGINAL SERIAL PLATE #_____________________ REPLACEMENT SERIAL PLATE #____________________ This appliance was converted on DATE :_______________________________________ from NG / LP to LP / NG BY _____________________________________________________________________________________________ with the conversion kit NGCKBL21 or LPCKBL21 by the above named qualified service ageny/technician which accepts the responsibility that the conversion has been completed properly as per instructions in this manual.