Download Print this page

Chromalox STAR-02A-11-PC Installation, Operation And Renewal Parts Identification

Type star radiant heater for portable installations

Advertisement

Quick Links

http://www.chromalox.com
Specifications – Table 1
Model
Figure
STAR-02A-11-PC
STAR-02A-81-P
STAR-02A-21-P
STAR-02A-71-P
STAR-02A-41-P
STAR-02A-61-P
STAR-05A-81-P
STAR-05A-21-P
STAR-05A-71-P
STAR-05A-41-P
STAR-05A-61-P
STAR-06A-83-P
STAR-06A-23-P
STAR-06A-71-P
STAR-06A-43-P
STAR-06A-63-P
STAR-14A-83-P
STAR-14A-23-P
STAR-14A-71-P
STAR-14A-43-P
STAR-14A-63-P
NA - Not Available
NR - Not Recommended
11-3/4"
Side View
© 2003 Chromalox, Inc.
Chromalox
Type STAR Radiant Heater
For Portable Installations
Amperage
Volts
KW
1 Phase
120
1.5
12.5
208
2
9.6
1
240
2
8.3
277
2
7.2
480
2
4.2
600
2
3.3
208
4.5
21.6
240
4.5
18.8
2
277
4.5
15.9
480
4.5
9.4
600
4.5
7.5
208
6
28.8
240
6
25.0
3
277
6
21.7
480
6
12.5
600
6
10.0
208
13.5
NR
240
13.5
NR
4
277
13.3
47.7
480
13.5
28.1
600
13.5
22.5
11-3/8"
Front View
Figure 1
®
BTU
3 Phase
A Height
NA
5118
NA
6824
NA
6824
28-1/2
NA
6824
NA
6824
NA
6824
NA
15354
NA
15354
NA
15354
49
NA
15354
NA
15354
16.7
20472
14.4
20472
20472
32-1/2
7.2
20472
5.8
20472
37.5
46062
32.5
46062
45038
55-5/8
16.2
46062
13.0
46062
28-1/2"
4
DIVISION
SECTION
SALES
(Supersedes PG433)
(Supersedes )
REFERENCE
MAY, 2003
DATE
Dimensions (In.)
B Width
D Depth
11-3/8
11-3/4
11-3/8
11-3/4
23-5/8
11-1/2
23-5/8
11-1/2
11-3/4"
11-3/8"
Side View
Front View
Figure 2
VTS
PG433-1
161-304901-001
Cord Ga./No. cond.
1 Phase
3 Phase
Comes w/cord & plug
14/3
NA
14/3
NA
14/3
NA
14/3
NA
14/3
NA
12/3
NA
12/3
NA
14/3
NA
14/3
NA
14/3
NA
10/3
12/4
10/3
12/4
10/3
12/3
12/4
12/3
12/4
NR
6/4
NR
6/4
6/3
10/3
12/4
10/3
12/4
49"

Advertisement

loading

Summary of Contents for Chromalox STAR-02A-11-PC

  • Page 1 46062 10/3 12/4 STAR-14A-63-P 13.5 22.5 13.0 46062 10/3 12/4 NA - Not Available NR - Not Recommended 11-3/4" 11-3/8" 11-3/4" 11-3/8" 28-1/2" 49" Side View Front View Side View Front View Figure 1 Figure 2 © 2003 Chromalox, Inc.
  • Page 2: Important Instructions

    7 feet from the front of the heater. 9. In order to prevent equipment damage, protect with a ground 3. Do not leave heater unattended while in operation. fault device such as Chromalox STAR-TG series monitor. SAVE THESE INSTRUCTIONS 4. Always disconnect heater when not in use.
  • Page 3: Optional Accessories

    8. Connect entrance wiring to pigtail leads “L1” and “L2”. Connect ground to screw provided. 9. Inspect to make sure wiring is per “Single Phase Wiring” above. OPTIONAL ACCESSORIES Chromalox STAR series radiant heaters can be field modified by Plugs adding optional kits. Refer to Chart A and B to select the proper kit.
  • Page 4 3 Pole, 4 Wire 15-50 C73.61 The above plugs are designed to be used with specific ranges of cable diameters. If not used with Chromalox Cable Kits, check cable man- ufacturers cable diameter to be sure plug fits selected cable.
  • Page 5: Maintenance

    8. Remove failed element and replace with a new element. before servicing or replacing heating elements. Replace only with genuine Chromalox "Arctic End" ele- ments. Use of other elements will cause excess temperatures The reflectors should be kept clean to obtain the maximum inside terminal box.
  • Page 6 RELATING HERETO, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE AND extent and in the manner that the same are warranted to Chromalox by Chromalox’s vendors, and then only STRICT LIABILITY) OR OTHER THEORIES, MUST BE COMMENCED WITHIN ONE (1) YEAR AFTER THE to the extent that Chromalox is reasonably able to enforce such warranty, it being understood Chromalox DATE OF SHIPMENT OR IT SHALL BE BARRED.

This manual is also suitable for:

Star-02a-81-pStar-02a-21-pStar-02a-71-pStar-02a-41-pStar-02a-61-pStar-05a-81-p ... Show all